Electromagnetic Flowmeter WMX Series

The WMX-Series are fanged electromagnetic fow meters for use in 4” to 10” pipe in municipal or industrial water and waste water applications where propeller meters have typically been used in the past. Because the WMX has no moving parts and has electrodes designed to discourage fouling, this magmeter performs well and requires much less frequent maintenance in applications where debris would impede propeller meters. 

There is no rotor to stop turning or bearings to wear out. Minimal straight pipe requirements allow WMX-Series meters to be used in piping confgurations where there is little space between the meter and an elbow.In chemical injection applications, the meter should be placed upstream of the injection line or far enough downstream for thorough mixing to occur before the meter.Rate and total indication are standard on both models. 

Units are customer-selected and factory-set. No set-up is required.The WMX101 is externally powered with 7-26 Vdc at 30 mA max (see NOTE in Specifcations). Two Lithium 3.6V “AA” batteries provide auxiliary power during power failures, allowing the meter to continue recording fow rate and total without interruption for the duration of the outage. Where external power loss is infrequent, battery life should exceed 10 years.



The 20-foot power cable also provides pulse output for use with a variety of Seametrics and other displays and controls for remote reading, data logging, pulse-to-analog conversion, and telemetry applications. High frequency pulse rate (required for use with 4-20 mA converters) is standard; additional pulse rates are optional.

The WMX104 is a battery-operated unit for use when pulse output is not required. The Lithium 3.6V “D” batteries are replaceable with an approximate 1-year life under continuous use, or more depending on the duty cycle. An optional input/output cable can be installed post-factory if needed for changing applications.



FEATURES

  • Simple and economical as a mechanical meter
  • No moving parts
  • Built-in pulse output
  • Minimal straight pipe required
  • Continuous battery or external power
  • Data logger compatible
  • Telemetry-ready

APPLICATIONS

  • Municipal water/waste water
  • Industrial water/waste water
  • Cooling tower water treatment
  • Well usage reporting
Specification 



Flow Meter Air Limbah

Flow meter limbah
waste water flow meter
Waste water flow meter banyak dipakai di indusri manufacture, oil and gas, pertambangan, hotel dan restoran serta di rumahsakit atau ditempat lainnya yang peduli terhadap lingkungan.
Waste water treatment banyak sekali jenisnya karena kandungan oil, limbah domistic hingga limbah karena proses chemical. Flow meter limbah yang mempunyai base water karena jenis limbah yang bermacam-macam maka pemilihan jenis waste water flow meter harus disesuaikan dengan penerapan di lapangan.

Namun ada beberapa point penting dalam menentukan jenis flow meter limbah ini dan yang perlu diperhatikan adalah:
Kapasitas flow rate dari air limbah yang dideteksi oleh sensor flow meter

– Sifat dari air limbah yang tingkat keasaman cukup ekstrim perlu pemilihan bahan flow meter.
– Kekotoran dari air limbah serta temperature limbah sendiri untuk menentukan jenis flow meter
– Pressure aliran air limbah yang menggunakan pompa atau sistem grafitasi
– Kandungan air limbah mungkin mengandung getah, lumpur seperti bubur kertas atau kotoran solid lainnya
– Lokasi Instalasi flow meter indoor atau out door
– Tingkat proteksi ecetrical apakah perlu water proof ( karena kemungkinan terendam air ) akibat banjir atau jalur pipa di saluran pembuangan air hujan.
– Jenis Indicator integral atau remote yang pasanganya didalam control room
– Jenis koneksi power electric AC atau DC atau dengan battery
– Jenis Koneksi body sensor, flange, fitting atau drat
– Jenis matrial sensor body Carbon steel, cast iron, Stainless steel atau Non Metal
Flow Meter limbah biasanya diaplikasikan di area yang kotor dan kesamannya ekstrim baik itu asam maupun basah, karena itu hendaknya jenis matrial flow meter untuk body sensor menggunakan stainless steel atau non metal agar lebih tahan lama dan tidak berkarat. Jika menggunakan stainless steel cukup menggunakan SUS 304 dan untuk non metal dapat juga digunakan PP atau PVC.
Pada banyak aplikasi flow meter yang dipasang di jalur pembuangan limbah yang tidak menggunakan pompa atau hanya mengandalkan gravitasi sering muncul persoalan akurasi nilai pengukuran flow rate dan totalizer karena itu untuk menyiasati hal ini bisa dilakukan dengan modifikasi installasi flow meter pada pipa keluaran maupun masukan agar akurasi pengukuran oleh sensor flow meter sekecil mungkin errornya.

Pada Proses Pengolahan air minum (Instalasi Pengolah air ) atau pun pada Proses Pengolah air limbah (Instalasi Pengolah air limbah / ipal) dimana Bahan baku diambil dari sungai kebanyakan menggunakan flow meter woltman atau flow meter turbine atau yang lainnya. Namun pada kebanyakan kasus air sungai yang tidak bersih (kotor) karena sampah, rumput, pasir, lumpur dan sebagainya  mengakibatkan flow meter atau water meter tersebut mengalami gangguan dan bahkan ada juga flow meter  menjadi tidak akurat bahkan macet. Hal ini dikarena karakteristik flow meter jenis turbine terdapat komponen yang terus bergerak, berputar sesuai dengan kecepatan aliran dalam flow meter tersebut. Adanya komponen yang bersentuhan dengan fluida air pada flow meter turbine menyebabkan adanya keausan pada bearing, bushing atau shaft dari rotor turbine flow meter. read more