Small Vortex Flow Meter For Liquids kofloc

Kofloc Small Karman Vortex Flow Meter For Liquids
FM0101/0102/0103/0105 SERIES

KOFLOC’s Karman Vortex Flow Meter FM Series provides an ideal tool for measuring and monitoring liquid flows, including cooling water and cleaning water. Since PPS resin is used for body material,all models of the series offer superior reliability and durability.

Features

  • Simple design that minimizes a dead space
  • Measurements of very small flows available (up to 0.5 L/min) 
  • Use of PPS resin has achieved a small,lightweight and rigid 
  • The sensor can be used for pure water or deionyzed water or deionyzed water and chemicals (the sensor is acid-/alkali-resistant).
  • These models are in the process of aplication for CE Marking
Standard Specifications
Model
FM0101
FM0102
FM0103
FM0105
Dimension
(a)
17.8
17.5
17.5
32.5
Dimension
(L)
80.6
80
80
110
Connection
(X)
R3/8
R1/2
R1/2
25A
Flow
range
0.5-4 L/min
2-16 L/min
4-40 L/min
10-150 L/min
Fluids
for measurement
Cooling
water, cleaning water, etc.
Measuring
accuracy
Within
±3.0% F.S
Repeatability
Within
±0.5% F.S
Outputs
S Type:
4-20mA
P Type:
Pulse (Open collector) (For w/o indicator only)
D Type:
With indicator
Supply
voltage
12-24VDC
Liquid
temperature range
0-70 celcius
Proof
pressure
1MPa
Amb.
temperature range
0 – 50 celcius 
Amb.
humidity range
5-90%RH
Applicable
cleanliness/
IP64
(Splashproof construction per JIS C 0920)
waterproofing
standards
Material
for wetted part
PPS
with 30% glass mixture
PPS w/o
glass mixture
Cable
length
W/o
indicator: 2 meters long; terminated/pretinned (presoldered)
With
indicator: 3 meters long; terminated/pretinned (presoldered)
Weight
W/o
indicator: 85 g (Sensor unit)
165 g
(Sensor unit)
With
indicator: 100 g (Sensor unit)
205 g
(Sensor unit)
Principle Measurement

When a columnar object ( object that generates vortices) is placed in the flow path a of a fluid, regulecalled karman vortex channels, are generated at the back of the object. Since the frequency of a vortex generated is linearly proportional to the flow velocity within a given range, the flow amount can be measured by counting the number of vortices.

These series models make use of the principle. When the frequency of each vortex generated is detected by incorporated vortex detector (piezoelectric device), the signal processing circuit outputs a signal which is linearly propotional to volume flow.

Steam Flow Meter


Alia Vortex Flow Meter
Vortex Flow Meter
Steam Flow Meter
Flow Meter Steam

ALIAVTX AVF7000 is a Vortex Flowmeter based on Von Karman theory of vortices generated by a bluff body in the pipe. The number of vortices are linearly proportional to the volumetric flow in the pipe.
The AVF7000 flow meters is versatile flowmeter widely used for Gases, Steam & Liquid applications. There are no moving parts and comes with either Flange or wafer connection. Standard configuration have local indication for flowrate and total flow as well as a 4-20mA output functions. The microprocessor design can filter out erroneous signals as well as interfence caused by pipe vibration.

FEATURES

  •  Simplified setup and self-diagnostic functions  
  •  Auto. Temperature & Pressure compensation   
  •  4-20 mA and pulse outputs, user selectable  
  •  a very wide selection of sizes  
  •  Wide temperature range which can up to 420 Deg. C  
  •  Non-volatile memory for setup and calibration
SPECIFICATION

Size: Local display:
10,15,20,25,32,40,50,65,80,100,125,150 4 lines LCD
200,250,300,350,400,450,500mm 4 digit flowrate
Measuring Range: 8 digit Totalizer
Steam – 1.6 to 540,000 Kg/Hr Current output:
Gas – 3 to 46,000 M3/Hr 4-20 mA (2 wire)
Liquid – 0.3 to 4950 M3/Hr Load
Material: 600 Ohm
Stainless Steel 301 / 304 / 316 Pulse output:
Accuracy: Scale Pulse(3 wire)
Liquid Rating
+/-0.7% value of reading 3 to 30VDC, 20mA Max.
Gas & Steam Communication:
+/-1.0% value of reading RS485
Repeatability: Data storage:
+/-0.2% value of reading Operation Parameter and Totalizer
Process Connection: Figures are stored by EEPROM for more
Flange / Wafer than 10 years
Flanges type Housing Material:
JIS 10K / JIS 20K / JIS 40K Aluminum Alloy
ANSI 150# / ANSI 300# / ANSI 600# Cable Entry:
DIN PIN 10 / PN 16 / PN25 / PN 40 2 X M20 *1.5
Wafer type Power supply:
DN40~DN250 12-36 VDC
without Temperature / Pressure Sensor Ni-MH Battery(3 years working Hours)
Temperature: Key Pad:
-40 ~ +280 Deg. C (Standard) 4 keys from internal for Programming
-40 ~ +420 Deg. C (Optional) and display control
Ambient Temperature: Option:
-20 ~ +60 Deg. C Pressure Sensor
Pressure: Pressure compensation
78 Kg/cm2 (Max.) Signal output
Protection: 0-30 mV DC(20 uA Power supply)
IP 65 Temperature sensor
Explosion Proof, Exd IIC T6 Temperature compensation
Intrinsically Safe, Eex ia IIC T4 Signal output
PT100 ohm (3 wires)