Brainchild PR20 – low-cost paperless recorder

 Brainchild PR20 – low-cost paperless recorder
Description
The new PR series paperless recorders are launched in full product range with outstanding specifications and features. PR series includes a low-cost PR10, a popular PR20 and a high-end PR30. Compared with the first generation VR series, PR series offers much more, for example recorders in 4.3” & 12.1” displays in addition to 5.6”, 100 msec. sampling rate, external channels, batch, custom display, more strict FDA 21 CFR part 11, handwriting messages, SD slot, 2 USBs, pulse input, field calibration, Web Server, email, 19 languages, IP65, and yet in shorter depth 167mm.

Features
1.Touch Screen, TFT, 65K color
2.100 msec. scan rate
3.Internal memory: 256 MB Flash
4.CPU: ARM Cortex-A8, 1Ghz
5.Standard: Ethernet, SD slot & USB
6.Option: RS232/422/485 & Pulse input
7.Protection: IP65 front & IP20 rear
8.Standards: CE, cULus & RoHS
9.Pulse input for flow applications
10.Direct Printer connectivity
11.Webserver & Email directly from Recorder
12.Remote IO channels, Virtual channels
13.Master & Slave, Modbus RTU and TCP protocols
14.Custom display pages similar to HMI
15.Batch operations, built in security & FDA 21 CFR part 11
16.19 international languages
Specification
1.Product position : medium size and powerful one, input numbers up to the highest 24 channels
2. Input numbers : 3, 6, 12, 18, 24 channels
3. True universal inputs : Thermocouples: J, K, T, E, B, R, S, N, L, U, P, W5, W3, LR, A1, A2, A3, M
RTD: Pt50, Pt100, Pt200, Pt500, Pt1000 (α=0.00385), Pt50, Pt100 (α=0.00391)Cu10 (α=0.00427), Cu50, Cu100(α=0.00426, 0.00428), Ni100, Ni200, Ni500,JPt50, JPt100, JPt200, JPt500, JPt1000 (α=0.003916)Ni1000 (α=0.00617) mA, V, mV
4. The fastest sampling rate : to reach 100 msec / dot, default setting at 1 sec / dot
5. Math, External channels, Batch,Custom display, FDA 21 CFR part 11 : only available by Plus versions
6. Display : 5.6″ TFT touch screen
7. Resolution : 640 x 480
8. MTFB backlight at 25°C : 30,000 hrs
9. Backlight : LED
10. Screen saver, Email : Yes
11. A faster CPU : ARM Cortex-A8, 1Ghz
12. Internal Flash memory : 256 MB
13. RAM : 256 MB
14. Ethernet : Modbus TCP/IP
15. RS-232/422/485 : optional RS-232 or RS-422/485 Modbus RTU
16.SD card Slot, USB host x 2 : standard, one USB in the front, another USB in the back
17. Pulse input : optional DI card offering either logic or high frequency pulse counter
18. START / STOP key : to start / stop record and to turn off the display only, not recorder itself so that a quick start possible
19. Calibration correction : on-site calibration possible, or using handy features of Offset and Gain for correction
20. Multilingual : convenient for local users by offering 19 languages including English, Japanese,Danish, Italian, Polish, Russian, Dutch, Korean, Thai, Turkish, Portuguese,Chinese(simplied, traditional), French, German, Spanish, Swedish,Brazil Portuguese, Czech, other languages negotiable
21. PC software Historical Viewer+ Configuration : standard
22. Extensive software Data Acquisition Studio : optional real-time monitoring
23. Power supply : 90-250VAC or 11-36VDC
24. Outer dimensions (W x H x L mm) : 144 x 144 x189
25. Shorter mounting depth (mm) : 171
17. DIN Panel cutout (W x H mm) : 137 x 137
26. Protection : IP65 front, IP20 rear
27. Operating temperature : 0°C to 50°C
28. Storage temperature : -30°C to 70°C
29. Safety standards to be available : CE, cULus, RoHS

PR30 Paperless Chart Recorder Brainchild

Paperless Recorders PR30 is high-end paperless recorder that an advanced paperless chart recorder with a built-in high resolution 12.1″ touchscreen display, up to 48 channels, plug & play IO cards, and internal Flash memory storage. Its compact size makes it a portable solution for laboratories, factories and classrooms alike.

Users can access onsite data either on the screen data or from a remote location via RS-232/RS-485/RS-422 serial interfaces or via Ethernet networking. The PR-30 includes standard configuration software featuring a historical viewer. Configuration can be done on a PC and then sent to the recorder. Historical data can be stored in flash ROM, Compact Flash Card, or on a remote host PC for data evaluation and print-out.
Features
  • 12.1″ Touch Screen, TFT, 65K color
  • 100 msec. scan rate
  • Internal memory: 256 MB Flash
  • CPU: ARM Cortex-A8, 1Ghz
  • Standard: Ethernet, SD slot & USB
  • Option: RS232/422/485 & Pulse input
  • Protection: IP65 front & IP20 rear
  • Pulse input for flow applications
  • Webserver & Email directly from Recorder
  • Remote IO channels, Virtual channels
  • Master & Slave, Modbus RTU and TCP protocols
  • Custom display
  • Two USB ports for downloading data or printer connection
  • Optional FDA 21 CFR part 11

Specification

 
Product position big size and high-end one, good for sophisticated applications, for example power industry
Input numbers 6, 12, 18, 24, 30, 36, 42, 48 channels
True universal inputs Thermocouples: J, K, T, E, B, R, S, N, L, U, P, W5, W3, LR, A1, A2, A3, M
RTD: Pt50, Pt100, Pt200, Pt500, Pt1000 (α=0.00385), Pt50, Pt100 (α=0.00391)Cu10 (α=0.00427), Cu50, Cu100(α=0.00426, 0.00428), Ni100, Ni200, Ni500,JPt50, JPt100, JPt200, JPt500, JPt1000 (α=0.003916)Ni1000 (α=0.00617) mA, V, mV
The fastest sampling rate to reach 100 msec / dot, default setting at 1 sec / dot
Math, External channels, Batch,
Custom display, FDA 21 CFR part 11
only available by Plus versions
Display 12.1″ TFT touch screen
Resolution 1024 x 768
MTFB backlight at 25°C 60,000 hrs
Backlight LED
Screen saver, Email Yes
A faster CPU ARM Cortex-A8, 1Ghz
Internal Flash memory 256 MB
RAM 256 MB
Ethernet Modbus TCP/IP
RS-232/422/485 optional RS-232 or RS-422/485 Modbus RTU
SD card Slot, USB host x 2 standard, one USB in the front, another USB in the back
Pulse input optional DI card offering either logic or high frequency pulse counter
START / STOP key to start / stop record and to turn off the display only, not recorder itself so that a quick start possible
Calibration correction on-site calibration possible, or using handy features of Offset and Gain for correction
Multilingual convenient for local users by offering 19 languages including English, Japanese,Danish, Italian, Polish, Russian, Dutch, Korean, Thai, Turkish, Portuguese,Chinese(simplied, traditional), French, German, Spanish, Swedish,Brazil Portuguese, Czech, other languages negotiable
PC software Historical Viewer+ Configuration standard
Extensive software Data Acquisition Studio optional real-time monitoring
Power supply 90-250VAC or 11-36VDC
Outer dimensions (W x H x L mm) 288 x 288 x 189
Shorter mounting depth (mm) 171
DIN Panel cutout (W x H mm) 281 x 281
Protection IP65 front, IP20 rear
Operating temperature 0°C to 50°C
Storage temperature -30°C to 70°C
Safety standards to be available CE, cULus, RoHS
Ordering Code
 

PR3006 (6 analog inputs) –
1 2 3 4 5 6 7
PR3012 (12 analog inputs) 
PR3018 (18 analog inputs) 
PR3024 (24 analog inputs) 
PR3030 (30 analog inputs) 
PR3036 (36 analog inputs)
PR3042 (42 analog inputs) 
PR3048 (48 analog inputs)
1 Relay outputs 0: none
1: 6 relays
2: 12 relays
3: 18 relays
4: 24 relays
2 Digital inputs 0: none
1: 6 channels
2: 12 channels
3: 18 channels
3 Analog outputs 0: none
1: 6 channels
2: 12 channels
4 Power A: 90-250 VAC, 50/60 Hz
D: 11-36 VDC
5 Communication 0: standard Ethernet
1: Ethernet + RS232
2: Ethernet + RS-422/485
6 Firmware 0: standard version
1: Plus version 1 with extra mathematics, external channels, batch & FDA 21 CFR part 11
2: Plus version 2 with custom edited display, an editing software Panel Studio to be supplied
3: Plus version 3 including Plus version 1+2 above
7 PC software 1: free basic software of Historical Viewer & Configuration
2: extensive software Data Acquisition Studio (RealTime Viewer + Historical Viewer + Configuration)
8 Mounting types, power cord & switch 0: panel mount, no power cord, no power switch
1: panel mount, no power cord, power switch
2: portable, UL & CSA power cord, power switch
3: portable, VDE power cord, power switch
4: portable, SAA power cord, power switch
5: portable, BS power cord, power switch
6: portable, no power cord, power switch
7: panel mount, UL & CSA power cord, power switch
8: panel mount, VDE power cord, power switch
9: panel mount, SAA power cord, power switch
A: paenl mount, BS power cord, power switch
9 Special options 00: none
S1: 16G SD card
S2: 32G SD card

PR series Paperless Recorder

Paperless Recorders PR20 Brainchild

The new PR series paperless recorders are launched in full product range with outstanding specifications and features. PR series includes a low-cost PR10, a popular PR20 and a high-end PR30. Compared with the first generation VR series, PR series offers much more, for example recorders in 4.3” & 12.1” displays in addition to 5.6”, 100 msec. sampling rate, external channels, batch, custom display, more strict FDA 21 CFR part 11, handwriting messages, SD slot, 2 USBs, pulse input, field calibration, Web Server, email, 19 languages, IP65, and yet in shorter depth 167mm.




The PR20 is a low-cost paperless chart recorder with a built-in high resolution 5.6″ touchscreen display, 6 channels, plug & play IO cards, and internal Flash memory storage. Its compact size makes it a portable solution for laboratories, factories and classrooms alike.

Users can access onsite data either on the screen data or from a remote location via RS-232/RS-485/RS-422 serial interfaces or via Ethernet networking. The PR-20 includes standard configuration software featuring a historical viewer. Configuration can be done on a PC and then sent to the recorder. Historical data can be stored in flash ROM, Compact Flash Card, or on a remote host PC for data evaluation and print-out.


Features
  • Touch Screen, TFT, 65K color
  • 100 msec. scan rate
  • Internal memory: 256 MB Flash
  • CPU: ARM Cortex-A8, 1Ghz
  • Standard: Ethernet, SD slot & USB
  • Option: RS232/422/485 & Pulse input
  • Protection: IP65 front & IP20 rear
  • Standards: CE, cULus & RoHS
  • Pulse input for flow applications
  • Direct Printer connectivity
  • Webserver & Email directly from Recorder
  • Remote IO channels, Virtual channels
  • Master & Slave, Modbus RTU and TCP protocols
  • Custom display pages similar to HMI
  • Batch operations, built in security & FDA 21 CFR part 11
  • 19 international languages
Specification

 
Product position medium size and powerful one, input numbers up to the highest 24 channels
Input numbers 3, 6, 12, 18, 24 channels
True universal inputs Thermocouples: J, K, T, E, B, R, S, N, L, U, P, W5, W3, LR, A1, A2, A3, M
RTD: Pt50, Pt100, Pt200, Pt500, Pt1000 (α=0.00385), Pt50, Pt100 (α=0.00391)Cu10 (α=0.00427), Cu50, Cu100(α=0.00426, 0.00428), Ni100, Ni200, Ni500,JPt50, JPt100, JPt200, JPt500, JPt1000 (α=0.003916)Ni1000 (α=0.00617) mA, V, mV
The fastest sampling rate to reach 100 msec / dot, default setting at 1 sec / dot
Math, External channels, Batch,
Custom display, FDA 21 CFR part 11
only available by Plus versions
Display 5.6″ TFT touch screen
Resolution 640 x 480
MTFB backlight at 25°C 30,000 hrs
Backlight LED
Screen saver, Email Yes
A faster CPU ARM Cortex-A8, 1Ghz
Internal Flash memory 256 MB
RAM 256 MB
Ethernet Modbus TCP/IP
RS-232/422/485 optional RS-232 or RS-422/485 Modbus RTU
SD card Slot, USB host x 2 standard, one USB in the front, another USB in the back
Pulse input optional DI card offering either logic or high frequency pulse counter
START / STOP key to start / stop record and to turn off the display only, not recorder itself so that a quick start possible
Calibration correction on-site calibration possible, or using handy features of Offset and Gain for correction
Multilingual convenient for local users by offering 19 languages including English, Japanese,Danish, Italian, Polish, Russian, Dutch, Korean, Thai, Turkish, Portuguese,Chinese(simplied, traditional), French, German, Spanish, Swedish,Brazil Portuguese, Czech, other languages negotiable
PC software Historical Viewer+ Configuration standard
Extensive software Data Acquisition Studio optional real-time monitoring
Power supply 90-250VAC or 11-36VDC
Outer dimensions (W x H x L mm) 144 x 144 x189
Shorter mounting depth (mm) 171
DIN Panel cutout (W x H mm) 137 x 137
Protection IP65 front, IP20 rear
Operating temperature 0°C to 50°C
Storage temperature -30°C to 70°C
Safety standards to be available CE, cULus, RoHS

Ordering Code
PR20 –
1 2 3 4 5 6 7
 
PR2003 (3 analog inputs) 
               0: none
               6: 3 relays + 3 DI
               C: 3 relays + 3 DI + 6 AO
PR2006 (6 analog inputs) 

               1: 6 relays
               3: 6 DI
               5: 6 AO
               6: 3 relays + 3 DI
               7: 6 relays + 6 DI
               A: 6 relays + 6 AO
               B: 6 DI + 6 AO
               C: 3 relays + 3 DI + 6 AO
               D: 6 relays + 6 DI + 6 AO
PR2012 (12 analog inputs) 

               0: none
               1: 6 relays
               2: 12 relays
               3: 6 DI
               4: 12 DI
               5: 6 AO
               6: 3 relays + 3 DI
               7: 6 relays + 6 DI
               8: 9 relays + 3 DI
               9: 3 relays + 9 DI
               A: 6 relays + 6 AO
               B: 6 DI + 6 AO
               C: 3 relays + 3 DI + 6 AO
PR2018 (18 analog inputs) 

               0: none
               1: 6 relays
               3: 6 DI
               5: 6 AO
               6: 3 relays + 3 DI
PR2024 (24 analog inputs) 

               0: none
2 Power A: 90-250 VAC, 50/60 Hz
D: 11-36 VDC
3 Communication 0: standard Ethernet
1: Ethernet + RS232
2: Ethernet + RS-422/485
4 Firmware 0: standard version
1: Plus version 1 with extra mathematics, external channels, batch & FDA 21 CFR part 11
2: Plus version 2 with custom edited display, an editing software Panel Studio to be supplied
3: Plus version 3 including Plus version 1+2 above
5 PC software 1: free basic software of Historical Viewer & Configuration
2: extensive software Data Acquisition Studio (RealTime Viewer + Historical Viewer + Configuration)
6 Mounting types, power cord & switch 0: panel mount, no power cord, no power switch
1: panel mount, no power cord, power switch
2: portable, UL & CSA power cord, power switch
3: portable, VDE power cord, power switch
4: portable, SAA power cord, power switch
5: portable, BS power cord, power switch
6: portable,no power cord, power switch
7: panel mount, UL & CSA power cord, power switch
8: panel mount, VDE power cord, power switch
9: panel mount, SAA power, power switch
A: panel mount, BS power cord, power switch
7 Special options 00: none
S1: 16G SD card
S2: 32G SD card
10: PID card
11: PID card+16G SD card
12: PID card+32G SD card
PR series Paperless Recorder


PR10 Paperless Recorders Brainchild

The PR10 is a low-cost paperless chart recorder with a built-in high resolution 4.3″ touchscreen display, 6 channels, plug & play IO cards, and internal Flash memory storage. Its compact size makes it a portable solution for laboratories, factories and classrooms alike.
Users can access onsite data either on the screen data or from a remote location via RS-232/RS-485/RS-422 serial interfaces or via Ethernet networking. The PR10 includes standard configuration software featuring a historical viewer. Configuration can be done on a PC and then sent to the recorder. Historical data can be stored in flash ROM, Compact Flash Card, or on a remote host PC for data evaluation and print-out.

Standard Ethernet and optional RS-232/RS-422/RS485 communication enable users to access onscreen data and setup remote monitoring via the RS serial interface or Ethernet networking. The Brainchild’s data retention is specified at a minimum of 10 years with zero power data retention.
Features

  • Touch Screen, TFT, 65K color
  • 100 msec. scan rate
  • Internal memory: 256 MB Flash
  • CPU: ARM Cortex-A8, 1Ghz
  • Standard: Ethernet, SD slot & USB
  • Option: RS232/422/485 & Pulse input
  • Protection: IP65 front & IP20 rear
  • Standards: CE, cULus & RoHS
  • Pulse input for flow applications
  • Direct Printer connectivity
  • Webserver & Email directly from Recorder
  • Remote IO channels, Virtual channels
  • Master & Slave, Modbus RTU and TCP protocols
  • Custom display pages similar to HMI
  • Batch operations, built in security & FDA 21 CFR part 11
  • 19 international languages
Specification

 
Product position low-cost one, good for replacing 6-dotting chart
recorders, and 1, 2, 3 pen recorders
Input numbers 3, 6 channels
True universal inputs Thermocouples: J, K, T, E, B, R, S, N, L, U, P, W5, W3, LR, A1, A2, A3, M
RTD: Pt50, Pt100, Pt200, Pt500, Pt1000 (α=0.00385), Pt50, Pt100 (α=0.00391)Cu10 (α=0.00427), Cu50, Cu100(α=0.00426, 0.00428), Ni100, Ni200, Ni500,JPt50, JPt100, JPt200, JPt500, JPt1000 (α=0.003916)Ni1000 (α=0.00617) mA, V, mV
The fastest sampling rate to reach 100 msec / dot, default setting at 1 sec / dot
Math, External channels, Batch,
Custom display, FDA 21 CFR part 11
only available by Plus versions
Display 4.3″ TFT wide touch screen
Resolution 480 x 272
MTFB backlight at 25°C 30,000 hrs
Backlight LED
Screen saver, Email Yes
A faster CPU ARM Cortex-A8, 1Ghz
Internal Flash memory 256 MB
RAM 256 MB
Ethernet Modbus TCP/IP
RS-232/422/485 optional RS-232 or RS-422/485 Modbus RTU
SD card Slot, USB host x 2 standard, one USB in the front, another USB in the back
Pulse input optional DI card offering either logic or high frequency pulse counter
START / STOP key to start / stop record and to turn off the display only, not recorder itself so that a quick start possible
Calibration correction on-site calibration possible, or using handy features of Offset and Gain for correction
Multilingual convenient for local users by offering 19 languages including English, Japanese,Danish, Italian, Polish, Russian, Dutch, Korean, Thai, Turkish, Portuguese,Chinese(simplied, traditional), French, German, Spanish, Swedish,Brazil Portuguese, Czech, other languages negotiable
PC software Historical Viewer+ Configuration standard
Extensive software Data Acquisition Studio optional real-time monitoring
Power supply 90-250VAC or 11-36VDC
Outer dimensions (W x H x L mm) 144 x 144 x189
Shorter mounting depth (mm) 171
DIN Panel cutout (W x H mm) 137 x 137
Protection IP65 front, IP20 rear
Operating temperature 0°C to 50°C
Storage temperature -30°C to 70°C
Safety standards to be available CE, cULus, RoHS
Ordering Code
PR10 –
1 2 3 4 5 6 7
 
1. Input PR1003 (3 analog inputs) 
               0: none
               6: 3 relays + 3 DI
PR1006 (6 analog inputs) 

               0: none
               1: 6 relays
               3: 6 DI
               6: 3 relays + 3 DI
               7: 6 relays + 6 DI
2  Power A: 90-250 VAC, 50/60 Hz
D: 11-36 VDC
3  Communication 0: standard Ethernet
1: Ethernet + RS232
2: Ethernet + RS-422/485
4. Firmware 0: standard version
1: Plus version 1 with extra mathematics, external channels, batch & FDA 21 CFR part 11
2: Plus version 2 with custom edited display, an editing software Panel Studio to be supplied
3: Plus version 3 including Plus version 1+2 above
5. PC software 1: free basic software of Historical Viewer & Configuration
2: extensive software Data Acquisition Studio (RealTime Viewer + Historical Viewer + Configuration)
6. Mounting types, power cord & switch 0: panel mount, no power cord, no power switch
1: panel mount, no power cord, power switch
2: portable, UL & CSA power cord, power switch
3: portable, VDE power cord, power switch
4: portable, SAA power cord, power switch
5: portable, BS power cord, power switch
6: portable, no power cord, power switch
7: panel mount, UL & CSA power cord,power switch
8: panel mount, VDE power cord, power switch
9: panel mount, SAA power cord, power switch
A: panel mount, BS power cord, power switch
7. Special options 00: none
S1: 16G SD card
S2: 32G SD card
10: PID card
11: PID card+16G SD card
12: PID card+32G SD card



I/O Modules for Easy Expansion

  • AI206 – 6 Analog Inputs
  • AI203 – 3 Analog Inputs
  • RO206 – 6 Relay Outputs
  • DI206 – 6 Digital Inputs
  • RD233 – 3 Relays & 3 Digital Inputs
  • AO206 – 6 Analog Outputs

Plus Version of Firmware

In addition to the standard firmware, an option is available that offers more features such as math, external channels, custom display, batch and FDA21 CFR part 11.

PR series Paperless Recorder

Paperless Recorders

The number of direct analog inputs varies by model with the PR10/20/30 offering up to 6, 24 and 48 respectively as well as optionally External channels input via Serial or TCP/IP Modbus; maximum external channels are 24, 48 & 96 channels respectively. Derived Math channels are optional with the PR10/20/30 offering 15, 40 & 60 channels respectively. All analog, external, derived & digital inputs have a 100ms total sample rate. All analog, external and digital input channels are freely configurable and named to suit your process requirements.

The new PR series paperless recorders are launched in full product range with outstanding specifications and features. PR series includes a low-cost PR10, a popular PR20 and a high-end PR30. Compared with the first generation VR series, PR series offers much more, for example recorders in 4.3” & 12.1” displays in addition to 5.6”, 100 msec. sampling rate, external channels, batch, custom display, more strict FDA 21 CFR part 11, handwriting messages, SD slot, 2 USBs, pulse input, field calibration, Web Server, email, 19 languages, IP65, and yet in shorter depth 167mm.

The PR Series display real-time measured data on the touch screen and saves data to internal memory that may be exported to external USB or SD cards as well as over a LAN with the optional PR-Data Acquisition Studio software.

Data logging supports operator freehand messages directly on the touch screen that may be saved with the Data files as well as the data files being started and stopped as a Batch operation with additional batch / lot information (optional). The data files as well as convenient report generation may be printed from the recorder via LAN to network printers or via its USB port directly to printers supporting PCL4 / PCL5 / PCL6 language.
Applications:
  • Ovens – Furnaces – Kilns
  • Environmental Chambers
  • 21 CFR21 Part 11 FDA Requirements
  • AMS2750E Heat Treating Requirements
  • Boilers
  • Sterilizers / Autoclaves
  • Power Generation Variables
  • Flow Applications / Totalizers
  • Water / Waste Water Flow
  • Test & Measurement Applications
With 200MB on-board RAM for data storage and reliable low cost SD or USB cards the PR Series is ideal for monitoring, recording and evaluating processes in a variety of applications and industries. With the optional firmware Plus 1, 2 or 3, the PR Series includes multiple additional functions including math, counters, totalizers, high frequency digital inputs, batch data logging, monitor and record external channels, create custom display views that support animation as well as meeting the requirements of CFR21 part 11.

With LAN connection the PR Series offers emails upon alarm/event conditions, interactive web server, time synchronization and direct printing to network printers.

Features

  • Touch Screen, TFT, 65K color
  • 100 msec. scan rate
  • Internal memory: 256 MB Flash
  • CPU: ARM Cortex-A8, 1Ghz
  • Standard: Ethernet, SD slot & USB
  • Option: RS232/422/485 & Pulse input
  • Protection: IP65 front & IP20 rear
  • Standards: CE, cULus & RoHS
  • Pulse input for flow applications
  • Direct Printer connectivity
  • Webserver & Email directly from Recorder
  • Remote IO channels, Virtual channels
  • Master & Slave, Modbus RTU and TCP protocols
  • Custom display pages similar to HMI
  • Batch operations, built in security & FDA 21 CFR part 11
  • 19 international languages

PR series Paperless Recorder