Fine tek Rotary Paddle switch

15.Rotary Paddle Level Switch-SE Series

    

Principle
Rotary Paddle Level SwitchThe
SE series operating principle is simple. A unit is usually located
through a bin wall at the top, middle or low level of a bin. During
normal operation (no material present) a synchronous motor rotates the
paddle at 1 RPM. When this paddle rotation is impeded by material,
surrounding the paddle, motor will stall and cause the Micro-switch to change state. (indicating an alarm or control)
  

Features




  • Airtight sealing device, outdoor application is available.


  • Unique
    sealing ring design, it can perform good dust protection to avoid the
    dust permeate into housing body along with the shaft.
  • The torque force is adjustable.
  • The performance of torsion is stable and reliable.
  • If the rotary paddle bears an extra overload, the motor will be appeared slide to prevent the inside mechanism damaged.
  • It
    is rationally designed, the inside mechanisms are easily tore down for
    checking, maintenance and replacement. It doesn”t necessary to remove
    the complete set from the tank.
  • Very suitable for small tank and material of low density
    16. Capacitance Level Switch-SA Series 

    Principle
    Capacitance Level SwitchThe
    capacitance level sensor measuring principle is base on the ”
    capacitance effects ” , when this level sensor is set on a silo, it will
    be formed a condenser between the detector electrode and the silo wall.
    The capacitance of this condenser varies proportional to the change of
    material specific inductivity ( DK value) of the material stored in the
    silo , when the more material substances increased in the silo, the more
    capacitance value added simultaneously, then it will let his interior
    circuit “s resonant signal to create a bigger amplitude ,and such a
    signal amplitude become more or less than factory default threshold
    value, the relay device will be energized.
     
      

    Features




    • No moving parts inside the device, it will be not affected by friction, which are suitable for powder or liquid application.


    • Various models are suitable for different application.
    • Operating temperature -20 ~ 200°C, Max. 800°C.
    • The sensitivity, which includes 10pf, 20pf and 40pf, is adjustable.
    • With timing delay design, timing adjustable range 0 ~ 6 seconds.
    • Voltage: 110V/220VacC or 24Vdc
    • Output: NPN transistor, 5A/250Vac and 5A/240Vac SPDT contact.
    • Standard connecting screw 1″ NPT, special specification are acceptable.
    • Enclosure protection IP65 or explosion-proof.
    • SA-75U Zener barriers inside provide intrinsic safety (Ex ia IIC) to SA17( )D type level switch.
      17. Vibrating Probe Level Switch-SC Series 


      Principle



      Vibrating Probe Level SwitchThe
      vibrating probe of level switch operated by using two piezoelectric
      elements built-in on vibration tube. The first piezoelectric element
      triggered by pulse signal that created from circuit to transport
      vibration energy out, and the other piezoelectric element receives the
      vibration and transmits it to output electric signal. While the probe
      contacts material, the detection signal will be decayed and the
      vibration will hold and send out the relay on.
      Vibrating probe of
      level switch provides reliable & maintenance-free for bulk solids.
      Just a simple mounting and calibration procedure that keep your facility
      in save and monitoring. This device can withstand fiercely  lateral
      loads and static electricity.
      For friendly use, Fail-safe is equipped as standard to prevent malfunction caused by power shortage.

       
       



      Features


      • Sturdy and durable design. No calibration needed.
      • Special design to avoid the accumulation of material on probe.
      • High / Low fail safe modes
      • Field-operatable in sensitivity adjustment to fit versatile density of 
        18. RF-Capacitance/ Admittance Level Switch-SB Series 

        Principle
        RF-Capacitance / Admittance Level SwitchIn
        order to eliminate false alarm given due to  medium with high viscosity
        sticking onto the probe , a special material acting as an insulation 
        electrode have been added in between the active section and the
        grounding section.
        As shown in the diagram, sensing probe always
        experience medium clogging on it and thereby produces a capacitance and
        resistance between the 3 parts. Since the electric field between the
        active section and the guard section is round shaped, there will be no
        current passing through the medium between the electrodes.
        The
        Admittance level switch uses this principle, to add a guard section
        between the active section and the grounding section to block the
        admittance current to reach the vessel wall from the medium between the
        active section and grounded  electrode. Although there would be a small
        amount of admittance current between the guard section and the active
        section, the circuit would not take this current value into account. Due
        to the guard section, only the admittance current change between the
        active section and the tank wall will be detected by the circuit, thus
        only when the sensing probe is in contact with the medium will there be a
        precise signal.

         
         

        Features



        • Not affected by material coating on the sensing probe.
        • Easy installation.
        • Stable operation, not affected by temperature.
        • Time delay function of 0~90secs.
        • Housing protection: IP65.
        • DPDT /5A output.
        • Maximum temperature: 550°C.
        • High / Low fail safe selectable features.
        • Applicable in liquid, syrup, solid, grain and interface detection.
          19. RF-Capacitance Level Transmitter-EB Series

          Principle
          RF-Capacitance Level TransmitterCapacitance
          Level Indicator: Utilizes the capacitance formed between the sensing
          probe and the metallic vessel wall. A high frequency sine-wave is
          applied between the probe and the vessel wall.
          A change of the medium level will induce a change in the current of the applied sine wave.
          From
          Z=1/2pfc, when the capacitance in the vessel increase, impedance will
          decrease and current will increase. Vice-versa, when the capacitance in
          the vessel is small, the impedance will increase and current will
          decrease accordingly.
            

          Features



          • Suitable for high temperature, high pressure and corrosive environment.
          • Not affected by noisy, dusty, misty and changes in the temperature.
          • No blind distance, ideal for different tanks.
          • Economic for large tanks
          • 4~20mA output compatible for most control systems and meters
            20. Ultrasonic Level Transmitter-EA Series 


            Principle



            The
            ultrasonic level Indicator is a low-cost, noncontact and
            easy-to-install measurement device. It is able to meet the every-day
            needs of commercial production, as well serving a more specialized role
            in the technologically-advanced aero-space industry, thus placing it
            firmly in the category of high-level measurement technology. Unlike
            other level indicators with limited uses, the easy-to-install ultrasonic
            level indicator is a highly-accurate device with enough specialized
            uses to ensure that the needs of the customer are met.

             
             



            Features



            • Non-contact style will not affected by material character (such as Pressure, Viscosity, Density).
            • Ultrasonic Level TransmitterMeasuring range is available with 2M, 5M, 7.5M, 10M,15M, 20M, 50M
            • Measuring accuracy +/-0.25% in liquid resolution is 2 mm.
            • Output : 2-wire, 3-wire and indicator (transducer and controller are separated).
            • Beam small angle, short blanking distance, is suitable for small tank.
            • Analog output : 4 ~20mA or 20 ~4mA.
            • Supply voltage: 110 / 220VAC or DC24V.
            • Suitable for powder and liquid application.
            • Fail-safe function, can accommodates the possibility of transducer or power failure.
            • Operating temperature: -20°C ~ 60°C. Enclosure rating: IP-65.
            • Communication port : RS232, RS485. Relay output : 1~5 x SPDT.
              20. Electromechanical Level Measuring System -EE Serie 

              Principle
              EE200
              series Electro-Mechanical Level Measuring System is consisted of plumb,
              cable wire, measuring pulley, position sensor, and control board.  When
              measuring, the sensing weight will drop down and cable wire will rotate
              the measuring pulley.  Position sensor and control board will calculate
              the distance of travel of the  sensing weight(medium level) based on
              how many rotations measuring pulley accomplishes.

               
               

              Features



              • 1 Measuring result immune from the interference of environment such as sound waves, dust, capacitance, or temperature change.
              • User-friendly with microprocessor-based design.
              • High level and low level alarm.
              • LCD Dot matrix: 8 x 2.
              • Analog output: 4-20mA dc.
              • Pulse output: Transistor output(NPN/PNP), Relay output(3A/250Vac)
              • Cable Break Alarm: System will detect cable  broken during measuring.
              • Plumb Buried Alarm: System will detect plumb buried by the medium.
              • Electromechanical Level Measuring System4 Forms of Start Mode: auto start, manual start, intelligent start, and external start.
              • Intelligent Start: Measuring interval is inverse  proportional to medium level.
              • Auto Return Setup: Prevent sensing weight from sliding into the tank to damage the equipment when tank is empty.
              • Material Fill-Up Protection: Reduce the possibility of plumb being buried.
              • Measuring range of 30m.
              • RS485 communication protocol.
              • Various selections of plumb                                                      



Horizontal Level Switch

DH Series
Level Switch
Horizontal Level Switch

Applications

The DH type level switch is used in the heavy oil, precipitate, sewage waste water, clean water, lubricating oil, and light oil tanks.

Operating principle
When the magnetic float type level switch  detects the surface level and emits the contact point output, the micro switch or reed  switch turns on or off. The two magnets completely separated by the  diaphragm each  operates. One is hanging at one end of the float and the other magnet is hanging on  the micro switch unit of housing.


Features

  • Complete waterproof  : The switch unit is completely separated.
  • Liability  : There is no problem since the allowed  contact point capacity is large with 250VAC  and 3A.
  • Easy Maintenance and Repair  : Since it is designed in a simple structure,  the maintenance and repair is easy.
  • Firm Float : The stainless steel float welded by the  argon gas is durable to high pressure and high temperature



Model number code system



Technical Data

Dimension [mm]

  • Model DH-100F
  • Model DH-100S
  • Model DH-200S

Table for Chamber Selection

Chamber Type & Installation

Terminal & Contact for SPDT. SPS

FLOAT LEVEL SWITCH

Float Level Switch
Quick Type Level Sensor
Daehan Sensor

PRINCIPLE
It makes output of on/off signal as the quick float moves up and down in which micro switch or reed switch installed. The on/off signal from the sensor controls supply/drain motor and/or high/low alarm. It is able to make up to 3 motors working together.

Applications

  • It is widely used for water tanks and tanks with high corrosiveness
  • It is widely used for tanks for drainage.

  • It is widely used for wastewater tanks

  • It is used in diverse water tanks

FEATURE

  • For controlling motors and alarming to control.
  • Easy to install and is generally used.
  • Widely used to waste water tank & sewage disposal tank.
  • Suitable for high viscosity liquid.
  • Strong against corrosion.
SPECIFICATION

Mountight
 2″PT or JIS 10K 100A / 80AFF
Connection
STD PF 1/2″
Oper. Temp
None
Oper. Pressure
 A.T.M
Material
Flange : Screw 2″
Cable : Soft PVC
Float : ABS
Weight : SS + PV

OPERATING PRINCIPLE

  • By installing the micro S/W inside the quick float, it is possible to operate it to the wanted location, operate the pump, or have the alarm sound by having the float to emerge due to buoyancy to become on (point A) or off (point B).
  • It is equipped with a function to step control (have connection control) 3 motors.
Dimension
Technical Data
Operating Sequence
Unit Selection Chart

Float Level Controller
Power Unit
Wiring
Unit Controller Technical Data

Level Switch

Fuel Level Switch
Parker Level Switch
Solar Level Switch
Tank Level Switch

Level Switch merupakan switch yang akan memberikan informasi atau tanda bahwa level dari suatu liquid ( liquid level ) atau powder level sudah mencapai pada setting yang ditentukan.
Level switch ini bisa bekerja pada media liquid normal seperti untuk water level, untuk oil seperti fuel level atau oil level atau solar level Namun ada juga yang bekerja untuk matrial not liquid seperti powder, biji-bijian tau lumpur. Jenis dari liquid yang mungkin bersifat korosif atau yang lainnya akan menentukan jenis matrial untuk floating switchnya. Jenis Level switch yang paling banyak digunakan adalah jenis float level switch baik untuk oil maupun air. Untuk jenis float level switch solar menggunakan matrial float dari stainless steel sedangkan untuk float level switch yang diaplikasikan di air banyak menggunakan jenis non logam.
Banyak sekali manufakture yang memproduksi jenis level switch seperti parker level switch yang banyak digunakan adalah parker JF-302T yang banyak digunakan untuk solar maupun Parker JF-302 yang secara luas digunakan untuk level water.

level switch – Level Sensor – Level Control – Fuel Level – Sewage Level – Water Level

Jenis Level Sensor

Level sensor yang diguankan untuk mengukur level dari suatu media baik level untuk liquid maupun level untuk lumpur dan powder mempunyai banyak jenis. Pengertian level sensor adlah alat instrumrnt yang dapat digunakan menedeteksi ketinggian atau level dari suatu matrial dengan fungsi sebagai monitor ataupun pengiriman data ataupun berfungsi sebagai switch.
Level sensor yang palig banyak kita ketahui dalah jenis level switch yang banyak digunakan di tanki tower di setiap rumah dimana untuk memberikan sinyal secara electric ke pompa air ketika level air dalam tanki mencapai batas level bawah maupun batas level atas dan jenis level sensor yang digunakan adalah floating level switch.

Sedangkan level sensor untuk kebutuhan industri transportasi seperti untuk mobil, truck, bus, dan alat berat ( mobile creane, excavator, loader dan lainnya ) kebanyakan untuk mendeteksi level bahan bakar dalam tanki bahan bakar baik berupa level solar maupun level bensin. Level sensor dipasang dalam tanki bahan bakar dan indicator di taruh di dash board untuk mengetahui stock bahan bakar.

Jenis Level Sensor

Level sensor
Level Switch
Level Transmitter
Level Solar
Level Gauge

Level sensor adalah sensor yang digunakan untuk mendeteksi ketinggian dari suatu aliran baik berupa bahan liquid, lumpur, powder maupun biji-bijian. Fungsi level sensor pada dasarnya adalah memberikan informasi baik berupa data maupun sinyal karena adanya perubahan ketinggian matrial baik didalam tanki, silo ataupun tempat terbuka dikarena adanya aliran dari matrial tersebut.
Pengukuran ketinggian atau level  ini bisa dilakukan secara terus menerus sesuai dengan perubahan ketinggian dari fluida maupun untuk mengukur ketinggian dari matrial pada titik tertentu baik itu pada level terendah, level menegnah maupun level puncak dengan menggunakan level sensor
Jenis level sensor ini bermacam-macam disesuaiakn dengan aplikasi dari matrial yang di deteksi dan wadah dari wadah yang tertutup berupa tanki, wadah terbuka berupa silo ataupun yang selalu berubah-ubah ketinggianya seperti sungai ataupun danau dan laut.
Bisa juga jenis level sensor didasarkan pada jenis bentuk matrial atau jenis matrial berupa liquid, powder, maupun sullury,  jenis level sensor didasrkan pada besarnya temperature, Pressure, sifat kimia dan lainnya.
Ada beberapa jenis level sensor didasrkan pada cara kerja yaitu :
1. Level Sensor untuk mendeteksi titik ketinggian dari matrial solid yang mengalir secara kontinyu baik berupa biji-bijian maupun powder
  • Vibrating pointial solid
  • Rotating paddle
  • Admittance-type
2.  Level Sensor untuk mendeteksi titik ketinggian dari matrial Liquid
  • Pulse-Wave Ultrasonic (Non Invasive)
  • Magnetic and mechanical float level measurement
  • Pneumatic level measurement
  • Conductive level measurement
3.  Level Sensor untuk mengukur keduaanya yaitu untuk mendeteksi titik ketinggian dan memonitor matrial solid dan liquidSensors
  • Ultrasonic level sensor
  • Capacitance level sensor
  • Optical interface level sensor
  • Microwave level sensor
4.  Level Sensor untuk mengukur level dari liquid secara kontinyu
  • Magnetostrictive level measurement
  • Resistive chain level measurement
  • Hydrostatic pressure level measurement
  • Air bubbler level measurement
  • Gamma ray level measurement
Type Level Sensor