SE series operating principle is simple. A unit is usually located
through a bin wall at the top, middle or low level of a bin. During
normal operation (no material present) a synchronous motor rotates the
paddle at 1 RPM. When this paddle rotation is impeded by material,
surrounding the paddle, motor will stall and cause the Micro-switch to change state. (indicating an alarm or control)
-
Airtight sealing device, outdoor application is available.
-
Unique
sealing ring design, it can perform good dust protection to avoid the
dust permeate into housing body along with the shaft. -
The torque force is adjustable.
-
The performance of torsion is stable and reliable.
-
If the rotary paddle bears an extra overload, the motor will be appeared slide to prevent the inside mechanism damaged.
-
It
is rationally designed, the inside mechanisms are easily tore down for
checking, maintenance and replacement. It doesn”t necessary to remove
the complete set from the tank. -
Very suitable for small tank and material of low density16. Capacitance Level Switch-SA SeriesPrincipleThe
capacitance level sensor measuring principle is base on the ”
capacitance effects ” , when this level sensor is set on a silo, it will
be formed a condenser between the detector electrode and the silo wall.
The capacitance of this condenser varies proportional to the change of
material specific inductivity ( DK value) of the material stored in the
silo , when the more material substances increased in the silo, the more
capacitance value added simultaneously, then it will let his interior
circuit “s resonant signal to create a bigger amplitude ,and such a
signal amplitude become more or less than factory default threshold
value, the relay device will be energized.Features
-
No moving parts inside the device, it will be not affected by friction, which are suitable for powder or liquid application.
-
Various models are suitable for different application.
-
Operating temperature -20 ~ 200°C, Max. 800°C.
-
The sensitivity, which includes 10pf, 20pf and 40pf, is adjustable.
-
With timing delay design, timing adjustable range 0 ~ 6 seconds.
-
Voltage: 110V/220VacC or 24Vdc
-
Output: NPN transistor, 5A/250Vac and 5A/240Vac SPDT contact.
-
Standard connecting screw 1″ NPT, special specification are acceptable.
-
Enclosure protection IP65 or explosion-proof.
-
SA-75U Zener barriers inside provide intrinsic safety (Ex ia IIC) to SA17( )D type level switch.17. Vibrating Probe Level Switch-SC Series
Principle
The
vibrating probe of level switch operated by using two piezoelectric
elements built-in on vibration tube. The first piezoelectric element
triggered by pulse signal that created from circuit to transport
vibration energy out, and the other piezoelectric element receives the
vibration and transmits it to output electric signal. While the probe
contacts material, the detection signal will be decayed and the
vibration will hold and send out the relay on.
Vibrating probe of
level switch provides reliable & maintenance-free for bulk solids.
Just a simple mounting and calibration procedure that keep your facility
in save and monitoring. This device can withstand fiercely lateral
loads and static electricity.
For friendly use, Fail-safe is equipped as standard to prevent malfunction caused by power shortage.
Features
-
Sturdy and durable design. No calibration needed.
-
Special design to avoid the accumulation of material on probe.
-
High / Low fail safe modes
-
Field-operatable in sensitivity adjustment to fit versatile density of18. RF-Capacitance/ Admittance Level Switch-SB SeriesPrincipleIn
order to eliminate false alarm given due to medium with high viscosity
sticking onto the probe , a special material acting as an insulation
electrode have been added in between the active section and the
grounding section.
As shown in the diagram, sensing probe always
experience medium clogging on it and thereby produces a capacitance and
resistance between the 3 parts. Since the electric field between the
active section and the guard section is round shaped, there will be no
current passing through the medium between the electrodes.
The
Admittance level switch uses this principle, to add a guard section
between the active section and the grounding section to block the
admittance current to reach the vessel wall from the medium between the
active section and grounded electrode. Although there would be a small
amount of admittance current between the guard section and the active
section, the circuit would not take this current value into account. Due
to the guard section, only the admittance current change between the
active section and the tank wall will be detected by the circuit, thus
only when the sensing probe is in contact with the medium will there be a
precise signal.
Features
-
Not affected by material coating on the sensing probe.
-
Easy installation.
-
Stable operation, not affected by temperature.
-
Time delay function of 0~90secs.
-
Housing protection: IP65.
-
DPDT /5A output.
-
Maximum temperature: 550°C.
-
High / Low fail safe selectable features.
-
Applicable in liquid, syrup, solid, grain and interface detection.19. RF-Capacitance Level Transmitter-EB Series
-
-
-