Gas Area Flow Meter Kofloc

An area flow meter has a float in a conical cylinder (tapered tube) with a larger end in the upper section and a smaller end in the lower section. The float moves up and down according to the intensity of the flow, and the position at which the float balances indicates the flow rate. Not only simple flow meters that merely measure the flow rate but also flow meters with a valve for flow control, flow meters with a load pressure fluctuation type flow controller, flow meters with a supply pressure fluctuation type flow controller, and flow meters with an alarm switch are available.

Gas Area Flow Meter Model 
  • Flowmeter with Precision Needle Valve MODEL RK1250 SERIES
  • Flowmeter with Precision Needle Valve MODEL RK1200 SERIES
  • Flowmeter with Bellows Needle Valve MODEL RK1500 SERIES
  • Low cost MODEL RK1700 SERIES
  • Purge Flowmeter with Needle Valve MODEL RK1650 SERIES
  • Purge Flowmeter with Needle Valve MODEL RK1600R SERIES
  • Simplified Flexible Flow Meter MODEL RK1100 SERIES
  • Flow Meter with Flow Controller MODEL 2503F SERIES
  • Flow Meter with Flow Controller MODEL 2504FR SERIES
  • High Precision Flowmeter MODEL RK1450 SERIES
  • High Pressure Flowmeter(for Sensitive Measurements) MODEL RK1400 SERIES
  • Purge Flowmeter MODEL RK1050 SERIES
  • Purge Flowmeter MODEL RK1000 SERIES
  • Low-Cost Flow Meter for Air and Nitrogen MODEL RK1150 SERIES
  • Reed Switch Flowmeters(for Alarm Switches) MODELS RK1970/RK1975/RK1976 SERIES
  • Flowmeters with Photosensor(for Alarm Switches) MODEL RK1812/RK1814 SERIES
  • Large Capacity Flowmeters MODELS RK2000/RK2005/RK2006 SERIES
  • Precision Flow Meter for Laboratory(with Stand for Precision Flow Measurement) MODEL RK1360 SERIES
  • Multiple Flow Meter with Needle Valve MODEL RK120X SERIES
  • Multiple Flow Meter MODEL RK140X SERIES
  • Flow Meter for Gas Mixing MODEL RK120XM SERIES
  • Acrylic Resin Flow Meter MODEL RK200 SERIES
  • Acrylic Resin Flow Meter MODEL RK500 SERIES
  • Large Capacity Flow Meter MODEL RK1950AP SERIES
  • Precision Flow Meter for Pressure Regulator MODEL RK4400 SERIES
Liquid Area Flow Meter Model
  • Flowmeter with Precision Needle Valve MODEL RK1200 SERIES
  • High Precision Flowmeter MODEL RK1450 SERIES
  • High Pressure Flowmeter(for Sensitive Measurements) MODEL RK1400 SERIES
  • Compact Reed Switch Flow Meter for Alarm Switches MODEL RK1930,RK1935 SERIES
  • Reed Switch Flowmeters(for Alarm Switches) MODELS RK1970/RK1975/RK1976 SERIES
  • Large Capacity Flowmeters MODELS RK2000/RK2005/RK2006 SERIES
  • Precision Flow Meter for Laboratory(with Stand for Precision Flow Measurement) MODEL RK1360 SERIES
  • Acrylic Resin Flow Meter MODEL RK400 SERIES
  • Acrylic Resin Flow Meter MODEL RK500 SERIES
  • Large Capacity Flow Meter MODEL RK1950AP SERIES

Flow Meter Akurasi tinggi

Kesalahan umum terbesar dalam pembelian  Flow meter adalah kurangnya data dan spesifikasi dalam memilih jenis, type atau model flow meter. Minimnya pengetahun flow meter tentang jenis, model dan type flow meter mempunyai peranan penting dalam menentukan pemilihan  flow meter. Biasanya Para Pembeli flow meter hanya didasrkan pada 2 kriteria saja, yaitu bisa membaca debit aliran ( bisa berfungsi) dan harga yang terjangkau. Sehingga saat beberapa lama flow meter digunakan yang terjadi adalah biaya maintenance yang tinggi dan tidak tercapainya tujuan dari pemasangan flow meter.
Untuk pengukuran Fluida yang sangat membutuhkan akurasi, dikarenakan proses maupun harga dari fluida yang mahal, biasanya di tuntut akurasi tinggi pada hasil pembacaan  flow meter . Ada beberapa flowmeter dengan berbagi jenis dan kelebihan serta kekurangan. Namun Begitu ada suatu flow meter dengan kemampuan akurasi yang sangat prima, dimana akurasi bisa mencapai 0.1% bahkan lebih.
Akurasi flow meter biasanya dalam pengoprasian tergantung pada setabilitas temperature dan stabilitas pressure dari aliran fluida. Perubahan pressure bisa juga mempengaruhi akurasi flowmeter begitu juga perubahan temperature akan mempengaruhi hasil totalizer dari volume fluida yang di baca oleh flow meter. Akurasi ini sangat penting khususnya jika flow meter digunakan untuk mengukur cairan yang harganya tidak murah, yang mengakibatkan selisih pengukuran bisa berakibat pada kerugian akumulasi angka yang besar.
Dengan kondisi dan karakteristik suatu fluida baik cairan maupun gas  seperti diatas sebaiknya menggunakan flowmeter jenis coriolis mass flow meter yang mampu menjangkau akurasi 0.1% atau dibawahnya. Beberapa keunnggulan dari coriolis flow meter ini adalah :
  • Akurasi bisa mencapai 0.1% atau lebih baik lagi
  • Repeatability : lebih baik dari 0.05%
  • Tahan terhadap korosi karena material sensornya stainless steel
  • Pperubahan temperature tidak mempunya pengaruh pada akurasi pembacaan
  • Aman jika Fluida mengandung partikel solid atau kotor karena tidak ada bagian parts sensor yang bergerak/berputar sehingga bisa dikatakan free maintenance.
  • Seting pembacaan dari mass bisa di setting ke volumetrik
  • Cocok untuk di operasikan pada filling dan custody
Jika karakteristik fluida yang sangat korosif serta mudah berubah bentuk karena perubahan temperature saat peroses dan cukup asam sebaiknya menggunkan flow meter jenis coriolis mass flow meter yang secara langsung menghitung mass dari cairan, sehingga perubahan volume karena perubahan temperature tidak merubah hasil dari pengukuran flow yang lewat  flow meter.

Dikarenakan Coriolis flow meter menggunakan material stainless steel untuk type standart ini sudah bisa mewakili syarat industri pengolahan makanan yang menuntut kelas material food grade serta tahan terhadap korosi sehingga bisa juga dikatakan food grade flow meter
Sehubungan harga dari fluida yang sangat mahal maka Coriolis mass flow meter sangat cocok sekali guna mencegah dan mengurangi kerugian jumlah fluida dan turunanya, yang disebabkan oleh selisih perhitungan dan pengukuran sebab akurasi dari mass flow meter je nis coriolis ini mencapai akurasi tinggi yaitu 0.05% hingga 0.2 % tergantung spesifikasi yang di inginkan.
Karena Coriolis mass flow meter ini bisa di pesan dengan custem maka bisa digunakan untuk berbagai stadart dari stadart JIS, ANSI, DIN dan lainna begitu juga jenis material bisa juga digunakan untuk asam yang punya PH ekstrim, Temperature ekstrim dari -45 to +210°C. Dan juga bisa diaplikasikan pada pressure hingga 345 bars.
Berikut Karakteristik dan keunggulan Coriolis Flow Meter yang di produksi oleh Rheonik dari germany 
APPLICATIONS
  • Suitable for virtually any mass flow application, such as: Batching, Dosing, General flow control, Injections, Filling
  • Loading of boats, vessels, rail tank wagons
  • High temperatures and other challenging applications
  • Highly viscous media (low pressure drop and excellent performance at low flow conditions)
  • Properly used for corrosive liquids and Low Flow 
  • Properly used for beverages that require  food grade instrument
FEATURES
  • The outstanding features include :  Suitable for pressure up to 450 bar
  • Size : 1/4″ – 12 ” : 
  • Measuring ranges : 0.002  kg/min to 25.000 kg/min ( depending on pipe size ) 
  • Accuracy   : 0.1% and better
  • Repeatability : better than 0.05%
  • Optimised solutions for your batching operation
  • Extra compact design with minimal space requirement
  • EEx Approvals (i.e. ATEX, CSA, …)
  • Custody Transfer Approvals (i.e. PTB, NMI, …)
  • As heavy duty version available (increased wall thickness of measuring pipes for additional safety – 250 bar)

ADVANTAGES 
  • No pressure effect – no deterioration of accuracy due to pressure changes by the patented Omega Shape
  • Medium flow rates in combination with high operating pressure
  • Patented torsion swinger design assures  most stable and drift free measurement,
  • Increased signal to noise ratio by torsion swinger
  • Longest life time and increased safety (low stress in welds and increased wall thickness against abrasion)
  • No moving parts, practically no maintenance
  • Removable connection block
Specification : 
  • Typical measuring ranges : 0.002  kg/min to 25.000 kg/min
  • Flow Accuracy :  0.1% and better
  • Repeatability  :  better ± 0.05% of rate
  • Density         :  better than  ± 0.001 g/cc
  • Temperature   : -200 to +350°C 
  • Pressure range : Measuring Loops max. 93 bar – max CL 600 / PN 40
  • Material of Wetted Parts :
    • 1.4571 / SS 316Ti (standard), 
    • 1.4539 / SS 904L on request, 
    • Hastelloy C22 on request
    • Tantalum and Other material on request
  • Housing : 
    • Stainless Steel: 1.4301 / SS 304 ( standart) and  others on request
    •  Protection class: IP 65 (Nema 4X) and higher on request 
  • Electrical connection
    • Junction box / aluminium coated (standard) IP 65 (Nema 4X) (Junction box in SS optional)
    • Cable entry M25 x 1.5 (M20 x 1.5, ½” and ¾” NPT optional)
    • Max cable length between RHM and RHE :
      • 100 m (330 ft)
      • 200 m (660 ft) only with factory approval
  • Approvals
    • ATEX (CESI 02 ATEX 053 X) : Ex II 1 G, EEx ia IIC T6-T1
    • CSA (220705) Class I, Div 1 and 2, Groups A, B, C and D;Type 3
    • Custody Transfer Approvals (PTB 1.32-97027224 and NMI TC 3382)
    • PED according to directive 97/23/EC available
    • 3A Sanitary Approvals
  • Transmitter and Display mounting : wall mounting, Pannel Mounting, Rack Mounting
  • Outputs :
    • 2 analog outputs, 
    • 1 frequency/pulse output 
    • 3 digital outputs (Lt, +/-, error…)
  •  Inputs :   2 inputs (hold, reset, zero)
  • Power supply :   
    • 230 VAC +/- 10% or
    • 115 VAC +/- 10% or    
    • 24 VDC 
    • Cable entries:   4 x M25 x 1.5 – others optional
  • Interface :  
    • RS 422/485/232 – optional
    •  HART – optional 
  • Power consumption : < 15 W

ElektroGas Solenoid Valve

The study of innovative solutions and the application of new technologies make it possible for continuous improvement of the complete range of products and, in many cases, an increase of their performance.

The experimentation of the new technical solutions and the very stringent reliability tests which every new product is subjected to, guarantee the safety and the quality of all products introduced into the market.

The accumulation of experience and know how achieved through many years of activity are always the starting point for every new

project.
VMH VMP SERIES
Safety shut off valves, slow opening and fast closing with hydraulic or pneumatic actuator The VMH type valve is a safety shut off valve for gaseous media operated by hydraulic actuator. It is suitable for gas blocking and releasing controls, as required in the main pipe of gas power burners, atmospheric gas boilers, industrial kilns and […]
VMR SERIES
Safety solenoid valves for air and gas, fast opening and fast closing type The VMR type valve is a fast opening solenoid valve that is normally closed. When the coil is not energized the spring works on the disc keeping the gas passage closed. When the coil is powered the valve opens. When power is switched off the […]
VML SERIES
Safety solenoid valves for air and gas slow opening and fast closing The VML type valve is a safety valve that is normally closed, with fast or slow opening and adjustable rapid section for initial gas flow. When not in working position the spring works on the disc keeping the gas passage closed. When the coil is powered […]
VMM SERIES
Multiple safety solenoid valve for gas regulating trains The VMM type valve is a combination of two valves in an only compact and versatile valve housing. The first valve is a fast opening safety solenoid valve. The second valve may be a fast opening or a slow opening solenoid valve to adjust the gas flow, […]
EVRMNC EVRM6NC SERIES
Safety solenoid valves for gas with manual reset, normally closed The EVRM-NC type valve is a manual reset safety valve that is normally closed. When the coil is not energized the spring works on the shutter keeping the gas passage closed. Simply by energizing the coil the valve does not open. It is necessary to manually […]
EVRMNA EVRM6NA SERIES
MODEL/TYPE:The EVRM-NA type valve is a manual reset safety valve that is normally open.A manual operation is therefore necessary to open the valve and set the mechanism consenting to maintain this state. The powering by means of line current and/or condenser discharge, induced by the leakage detector, causes tripping of the mechanism and consequent closing of the gas passage. If energizing of the sensor persists due to the presence of gas, the valve remains under power and does not 
VF VFH SERIES
Butterfly valves for air and gas  VF and VFH butterfly valves are designed for regulation and control of air and gas flow. Valves can be operated manually using a lever (to setup the high-fire rate of the burner) or automatically using a servomotor (modulating or staged control) or a solenoid actuator (two-stage control). The setting can […]
VRA VLA VTA SERIES
Solenoid valves for combustion air regulation The VRA/VLA/VTA types are normally closed solenoid valves for cold combustion air regulation. When the coil is not energized the spring works on the disc, keeping the adjusted minimum passage of air. When powering the coil the valve opens, moving the disc to the maximum open position. When power […]
SR SL ST SERIES
Solenoid actuator for butterfly valves Solenoid actuators are designed to operate VF and VFH butterfly valves. When the coil is not energized the inner spring pushes down the plunger and, by means of a gear mating, shifts the connected valve to the minimum opening position. When the coil is powered the plunger moves up fast (SR) […]
MZ SERIES
Servomotor for butterfly valves  Servomotors MZ are designed to operate VF and VFH butterfly valves. They consist of a multi-stage spur gearbox with DC motor, driven by an electronic control unit. This allows a high torque and adjustable running time. MZ3 type is suitable for basic adjusting position, operated by cams connected to driving shaft. MZ5 […]
FG SERIES
Gas filters Filters for gas pipelines with very high holding capacity of dust and impurities, suitable for protection of devices installed downstream. The filter cartridge is a steel supported frame covered with a high performance nonwoven made of polypropylene fibres, which satisfy the stringent requirements of Fire Class F1 according to DIN 53438 and thus […]
PCS SERIES
Proof of closure switch The PCS is a mechanically activated switch for monitoring the position of the valve plate. This device can be fitted to valves and actuators. It is designed in accordance with norm EN161 to detect the closed status. The compact, robust and functional design permits a simple and quick installation even on […]
PSG SERIES
The PSG 901 is an adjustable pressure switch for monitoring overpressure of air and non-aggressive gases (families 1-2-3 EN437).
The pressure switch is available in different pressure ranges, all with male threaded connection G1/4. Special versions are available for use with aggressive gases.
The compact, robust and functional design permits a simple, quick, and essentially maintenance free installation.

Delta Oil Burner

.The study of innovative solutions and the application of new technologies make it possible for continuous improvement of the complete range of products and, in many cases, an increase of their performance.
The experimentation of the new technical solutions and the very stringent reliability tests which every new product is subjected to, guarantee the safety and the quality of all products introduced into the market.
The accumulation of experience and knowhow achieved through many years of activity are always the starting point for every new
project.
A, AD TYPE
Modern and compact oil burners pump, designed to pump fuel from the tank to the burner nozzle, at the required pressure. The A – AD type pump is made of a pumping unit integrated in a cast iron housing, connected to an aluminium pressure die casting distributor. It is provided with bidirectional nozzle ports, pressure […]
VU TYPE
The DELTA Universal Fuel Unit is an efficient and modern oil pump, designed for pumping oil in high pressure oil burners and transfer pump applications. The mounting flange, hub and shaft sizes are manufactured to international standards (EN 225), and the same unit is provided with bilateral nozzle port, and is suitable for clockwise and […]
VD TYPE
The DELTA VD fuel unit is an efficient modern oil burner pump with compact design and since its mounting flange, hub and shaft sizes are manufactured to international standards (EN 225), it can be fitted to every oil burner. The DELTA fuel unit type VD is designed for pumping oil in high pressure oil burners […]
VM TYPE
The DELTA fuel unit type VM provides an efficient and modern oil burner pump with compact design since its mounting flange, the hub and the shaft of the international standard. (DIN 24220, EN 225) correspond, they can be fitted to every oil burner
EV-F84 TYPE
The Delta type EV electrical solenoid valve is a normally closed one-way direct acting valve. It is designed for use as an interrupter valve or as a shut-off valve. The body is made of brass, the core is of solenoid quality steel and the seal is a synthetic rubber which is suitable for use with light […]

Flow Meter Turbin

Turbine Flow Meters
Flow Meter Turbin
Liquid Flow Meter

Flow Meter Turbine (turbin aksial)
diciptakan oleh Reinhard Woltman dan merupakan flow meter yang akurat dan dapat
diandalkan untuk liquid dan gas. Flowmeters Turbin menggunakan energi mekanik
dari cairan yang mengalir guna memutar sebuah “pinwheel” (rotor).
Blades pada rotor dibuat miring dengan sudut tertentu layaknya baling-baling,  untuk mengubah energi dari aliran fluid menjadi
energi rotasi. Poros rotor berputar pada bushing/bearing dimana ketika cairan
bergerak lebih cepat, rotor berputar secara proporsional lebih cepat.

Rotasi poros dapat dirasakan secara
mekanis atau dengan mendeteksi gerakan blade. Gerakan blade terdeteksi secara magnetis,
dengan masing-masing blade atau bagian tertanam dari logam akan menghasilkan
pulsa. Ketika liquid bergerak lebih cepat pada flow meter turbine, maka akan lebih banyak menghasilkan
pulsa yang akan sebanding dengan kecepatan aliran fluida. Sensor Pick-up pada flow meter turbin akan memproses
sinyal pulsa untuk menentukan aliran fluida. Pemancar dan sistem gerakan yang tersedia untuk menangkap aliran di kedua arah arus maju dan mundur.

Sensor pick-up menghasilkan pulsa
secepat berputar nya impeller, ini memberikan reaksi waktu yang sangat cepat sehingga membuat jenis flow meter ini  sangat cocok untuk aplikasi batching. Pulsa yang
dihasilkan oleh sensor pick-up merupakan pulsa per satuan volume, juga disebut
sebagai faktor-k.

Turbine Flow meters  dapat digunakan untuk mengukur kecepatan
aliran dari liquid, gas dan uap dalam pipa, seperti hidrokarbon, bahan kimia,
air, cairan kriogenik, udara, dan gas industri. 
Yang perlu diperhatikan dalam menentukan
turbine flow meter hendaknya berhati-hati pada cairan yang kotor ( mengandung
sampah, pasir dan solid lainnya) karena kotoran akan bisa menghambat akurasi
dan bahkan akan gagal karena rotor tidak bisa berputar akibat tersangkut
kotoran. Begitu juga untuk cairan yang non-pelumas, karena flowmeter dapat
menjadi tidak berfungsiatau akurasinya menyimpang terlalu jauh karena itu ada flowmeters
turbin
memiliki kelengkapan grease untuk digunakan pada cairan yg tidak mempunyai sifat pelumasan. 

Selain itu, turbin flowmeters yang dirancang untuk tujuan tertentu, misalnya
untuk layanan gas alam, sering dapat beroperasi pada rentang temperatur yang
terbatas (misalnya sampai 60 º C) dimana operasi pada suhu yang lebih tinggi
dapat merusak flowmeter tersebut.
Turbine
Flowmeter
ini lebih baik jika diterapkan untuk cairan sanitasi, relatif bersih,
dan korosif dalam ukuran sampai dengan sekitar 24 inci. Flowmeters turbin yang  kecil dapat dipasang langsung di pipa, tapi
ukuran dan berat flowmeters turbin yang lebih besar mungkin memerlukan
instalasi pondasi yang kuat. Aplikasi Turbin Flowmeters  kurang akurat
pada tingkat kecepatan aliranyang rendah karena dapat  memperlambat putaran rotor. sementara itu untuk installasi turbine flow meter ada yang secara inline menggunakan koneksi flange ulir dan ada juga yang menggunakan metode insert bisanya dikenal dengans sebutan insertion turbine flow meter.

 Begitu juga untuk kecepatanaliran
fluida  yang terlalu tinggi dapat
meneyebabkan keausan pada bushing ataupun bearing ataupun shaft rotor karena
itu hendaknya dalam mengoperasikan flowmeters kurang lebih  sekitar 5 persen lebih tinggi dari kecepatan
aliran maksimal sebagaimana ditentukan oleh manufacture.  Dalam beberapa aplikasi, penggantian bantalan
mungkin perlu dilakukan secara rutin dan berkakibat pada tingginya maintenance
cost. Begitu juga Aplikasi pada fluida yang kotor  umumnya harus dihindari sehingga mengurangi
kemungkinan life time flowmeter dan kerusakan bantalan/bearing/shaft rotor,  karena turbin flowmeters memiliki bagian yang
bergerak yang mengalami keausan sesuai dengan waktu penggunaan.

Sedangkan untuk segi bahan material dari jenis turbine flow meter ini ini ada cukup bervariasi dari bahan carbon steel , stainless steel baik yang food grade maupun yang tidak yang banyak digunakan untuk industri makanan bahkan dari bahan non metal seperti PVC, PP, Teflon dan lainnya yang banyak digunakan untuk chemical flow meter.



Memilih Type Flow Meter

Jenis Flowmeter

Flow meter merupakan instrumen guna mengukur aliran dari suatu fluida baik liquid ( liquid flowmeter), sludge ( sludge flow meter) maupun gas ( flow meter gas), baik bertemperatur rendah hingga temperatur tinggi. Dalam memilih flow meter harus disesuaikan dengan kondisi fluid dan fungsi flowmeter itu sendiri. Karakteristik dari fluida yang diukur oleh flow meter sangat luas  mulai dari tingkat corosive fluida dimana untuk fluida yang tingkat keasamannya tinggi mungkin lebih cocok jika menggunakan  flowmeter dari bahan PVC / non logam.
Untuk fluida yang bertemperatur tinggi tentunya digunakan matrial lain. Begitu juga untuk tingkat kepekatan matrial fluida jenis flow meter harus disesuaikan. Untuk fluida yang diaplikasikan pada bahan makanan atau obat-obatan yang menuntut bahan pipa dan bahan flowmeter yang harus food grade lebih cocok kalo dipakai stainles steel SUS 316L. Dan untuk lingkungan yang corisive seperti di laut mungkin body dan flange flow meter lebih pas jika menggunakan stainless steel.

magnetic flow meter
Water Meter

Karena dibutuhkan ketelitian dan pemahaman akan karakteristik fluid serta manfaatnya , serta cara kerja Flowmeter dan fungsi flow meter itu sendiri. Ada beberapa variabel yang harus kita tentukan dalam MEMILIH FLOW METER pada saat penentuan type flow meter dan model flowmeter  yang cocok dengan aplikasi yang kita harapkan, varibel pemilihan flow meter tersebut dapat dimasukan kedalam pertanyaan sebagai berikut :
1. Jenis Fluid yang akan digunakan pada flow meter : gas, water, chemical, oil , liquid gas, sludge, dll
2. Pengukuran flow meter hanya pada flow atau total fluid yang mengalir atau kedua2nya
3. Viscosity dari fluid, Kebersihan/kekotoran dari fluid ( lumpur, banyak kotoran atau bersih ) yang mengalir ke flow meter
4. Tujuan dari Flow meter : sebagai alat ukur flow, total volume, control, switch,  pengiriman sinyal electric yang berfungsi sebagai control ataupun data ke komputer atau Hand phone lewat sms.
5. Perlu tidaknya display pada flow meter atau electronic signal out put or electrical out put.
6. Besaran ( max dan min ) dari Flow rate, working Pressure, Temperature dari fluid yang akan diukur flow meter
7. Perlu tidaknya sistem kedap air pada flow meter ( water proof) atau area yang mudah terbakar atau explossive atau  yang setandart
8. Penggunaan untuk bahan kimia dan makanan seperti tingkat keasaman dari fluid atau perlu food grade untuk matrial flow meter yang sering digunakan di industry obat atau makanan dan minuman.
9. Ukuran dari pipa dimana flow meter ini di install termasuk menggunakan sistem sambungan flange atau ulir atau fitting
10. Sistem insatallasi flow meter : Vertical atau horizontal
11. Keterangan lain yang diperlukan dalam memilih jenis flow meter karena pada dasarnya flow meter bisa dibuat/dipesan sesuai dengan keinginan pemesan (custom)

Flow meter mempunyai banyak jenis dan berdasarkan cara kerja dapat dibagi dalam beberapa type:

bahan flow meter, cara kerja flow meter, Flow meter, flowmeter, fungsi flow meter, liquid flowmeter, memilih flow meter, sludge flow meter, type flow meter, water meter