Gastec Calibration Gas Generating Equipment PD-1B And PD-1B-2

Calibration gas generating equipment 


The Permeater is a gas generator for calibration purposes that utilises permeation and diffusion tubes to generate the calibration gas. When the permeation and diffusion tubes are set at a constant temperature, the weight of both the permeating and the evaporating diffusion gas will be respectively set at constant levels.
In this manner, calibration gas is continuously generated by setting both tubes at a constant temperature and providing a constant flow of dilution gas such as air or nitrogen.
This method is highly reliable because gas concentration levels are determined based on the dynamic weight loss obtained from measurements such as rate of permeation diffusion or evaporation diffusion as well as the quantity of dilution gas calculated by weight.
[PD-1B]
Even calibration gas of very low concentrations can be continuously generated

[PD-1B-2]
It is possible to have two ventilation systems and to generate two kinds of calibration gas simultaneously
Features
·         Highly reliable because concentration levels are determined by calculating weight loss based on
·         Measurements and dilution gas volume
·         Many types (both organic and inorganic) of low-concentration calibration gases) can be generated
·         Gas for calibration of all organic solvents (as long as they are stable in their liquid state or at normal temperatures) can be generated
·         Gas for calibration can be generated continuously for longer periods of time
·         Calibration gas can be easily generated in a wide range of concentrations

 

     

Gastech Hand-held H₂S detector [HS-6A^HS-6A-S]

Normal
0

false
false
false

EN-US
X-NONE
X-NONE

MicrosoftInternetExplorer4

/* Style Definitions */
table.MsoNormalTable
{mso-style-name:”Table Normal”;
mso-tstyle-rowband-size:0;
mso-tstyle-colband-size:0;
mso-style-noshow:yes;
mso-style-priority:99;
mso-style-qformat:yes;
mso-style-parent:””;
mso-padding-alt:0cm 5.4pt 0cm 5.4pt;
mso-para-margin-top:0cm;
mso-para-margin-right:0cm;
mso-para-margin-bottom:10.0pt;
mso-para-margin-left:0cm;
line-height:115%;
mso-pagination:widow-orphan;
font-size:11.0pt;
font-family:”Calibri”,”sans-serif”;
mso-ascii-font-family:Calibri;
mso-ascii-theme-font:minor-latin;
mso-fareast-font-family:”Times New Roman”;
mso-fareast-theme-font:minor-fareast;
mso-hansi-font-family:Calibri;
mso-hansi-theme-font:minor-latin;}

Hand-held H₂S detector

[HS-6A^HS-6A-S]
 
Feature
•Slim / Compact and lightweight, only 100g
•The first model of this size to allow remote control
measurements
•Explosion proof
•RFI/EMI Shielding
•Simple auto zero calibration procedure
•Low power consumption

Specification
1.Measurement range: 0 – 30.0 ppm (enhanced range: 30.1 –
50.0 ppm)
2.Measurement method: Controlled potential electrolysis
method
3.Sampling method: Diffusion
4.Display: Digital LCD
5.Indicating accuracy: +/-1.5 ppm of full scale at time of
calibration
6.Alarm threshold and signal: Intermittent sound and
blinking warning lamp at 10 ppm, continuous alarm sounds and lamp lights up at
30 ppm
7.Power source: Two size AAA alkaline batteries for over
1000 hours (without alarm signal being emitted)
8.Dimensions: 42W x 26D x 130H (mm)
9.Weight: 100g
10Explosion proof: Certified by Japan Ministry of Health,
Labour and Welfare (Class 2G3 Certification No.55546)
*The products may not be sold depending on countries and
regions.

Gastec Oxygen Sensor

Galvanic cell sensor



This galvanic cell sensor that measures oxygen concentration has been in use since the mid-1960s to detect (and alert) oxygen deficiency throughout all industries.
Features
·          1. No technical expertise is necessary
·          2. Compact and lightweight
·           3. Outstanding performance with instant real-time measurement
·            4. Oxygen metre of intrinsically safe explosion-proof design
·            5. No electric power is necessary to operate the sensor
·            6. Low-priced oxygen meters are now a reality
A broad range of sensor types, suited for various kinds of oxygen meters, are available from GASTEC: firmly-installed types, portable or stationary ones, operating on the principle of diffusion or suction.
The measurement principle involves an electrolyte-soluble metal anode and an insoluble metal cathode that are immersed in the electrolyte. As the metal of the anode dissolves, it emits electrons that reach the cathode.
In the cathode, the oxygen penetrating the thin membrane film absorbs the electrons emitted by the anode. The flow (current) of this electron is proportional to the oxygen concentration penetrating the membrane film, and the oxygen concentration can be measured with a metre. Since the reaction occurs spontaneously, this sensor type requires no power source.

Delta Pumps Military Applications

Military Applications


Low pressure fuel pump fitted in a special oil burner designed for U.S.Army
– Heating capacity 8.8-23.5 kW
– Less than 10 ppm CO
– Temperature -15°C/+60°C
– Self priming, high lift, single line

Elektrogas Delta Pumps Hydraulic Operators

Hydraulic Operators



Transfer oil pump fitled intro hydraulic operators for swing-leaf gates.
          Capacity 20-70L/h @2800 rpm
          Pressure 10-40 bar
          Temperature-20°C/+80°C

Elektrogas Delta Pumps Chemical Industry

Chemical Industry

Pump for dosing and mixing of aggressive chemical substances.– Capacity 60 Kg/h @ 1400 RPM– Pressure 10-40 bar– Fluid viscosity 8800 cps

Elektrogas Delta Pumps Shut-Off Valves EV-F84 type

EV-F84 type

The Delta type EV electrical solenoid valve is a normally closed one-way direct acting valve. It is designed for use as an interrupter valve or as a shut-off valve. The body is made of brass, the core is of solenoid quality steel and the seal is a synthetic rubber which is suitable for use with light distillate oils and other fluids that are compatible with the above materials. All valves are 100% tested and are fully warranted.

Delta Pumps VM Type Elektrogas

VM Type

Die DELTA Brennstoffpumpe Typ VM stellt eine effiziente und moderne Ölbrennerpumpe in kompakter Bauweise dar. Da die Abmessungen ihres Montageflansches, der Nabe und der Welle der internationalen Norm (DIN 24220; EN 225) entsprechen, kann sie an alle Ölbrenner angebaut werden.