Flow Control Valve Kofloc
Gas Area Flow Meter Kofloc
- Flowmeter with Precision Needle Valve MODEL RK1250 SERIES
- Flowmeter with Precision Needle Valve MODEL RK1200 SERIES
- Flowmeter with Bellows Needle Valve MODEL RK1500 SERIES
- Low cost MODEL RK1700 SERIES
- Purge Flowmeter with Needle Valve MODEL RK1650 SERIES
- Purge Flowmeter with Needle Valve MODEL RK1600R SERIES
- Simplified Flexible Flow Meter MODEL RK1100 SERIES
- Flow Meter with Flow Controller MODEL 2503F SERIES
- Flow Meter with Flow Controller MODEL 2504FR SERIES
- High Precision Flowmeter MODEL RK1450 SERIES
- High Pressure Flowmeter(for Sensitive Measurements) MODEL RK1400 SERIES
- Purge Flowmeter MODEL RK1050 SERIES
- Purge Flowmeter MODEL RK1000 SERIES
- Low-Cost Flow Meter for Air and Nitrogen MODEL RK1150 SERIES
- Reed Switch Flowmeters(for Alarm Switches) MODELS RK1970/RK1975/RK1976 SERIES
- Flowmeters with Photosensor(for Alarm Switches) MODEL RK1812/RK1814 SERIES
- Large Capacity Flowmeters MODELS RK2000/RK2005/RK2006 SERIES
- Precision Flow Meter for Laboratory(with Stand for Precision Flow Measurement) MODEL RK1360 SERIES
- Multiple Flow Meter with Needle Valve MODEL RK120X SERIES
- Multiple Flow Meter MODEL RK140X SERIES
- Flow Meter for Gas Mixing MODEL RK120XM SERIES
- Acrylic Resin Flow Meter MODEL RK200 SERIES
- Acrylic Resin Flow Meter MODEL RK500 SERIES
- Large Capacity Flow Meter MODEL RK1950AP SERIES
- Precision Flow Meter for Pressure Regulator MODEL RK4400 SERIES
- Flowmeter with Precision Needle Valve MODEL RK1200 SERIES
- High Precision Flowmeter MODEL RK1450 SERIES
- High Pressure Flowmeter(for Sensitive Measurements) MODEL RK1400 SERIES
- Compact Reed Switch Flow Meter for Alarm Switches MODEL RK1930,RK1935 SERIES
- Reed Switch Flowmeters(for Alarm Switches) MODELS RK1970/RK1975/RK1976 SERIES
- Large Capacity Flowmeters MODELS RK2000/RK2005/RK2006 SERIES
- Precision Flow Meter for Laboratory(with Stand for Precision Flow Measurement) MODEL RK1360 SERIES
- Acrylic Resin Flow Meter MODEL RK400 SERIES
- Acrylic Resin Flow Meter MODEL RK500 SERIES
- Large Capacity Flow Meter MODEL RK1950AP SERIES
Flow Meters and Controller for Gas Kofloc
- Gas Flow Instrument
- Liquid Flow Instrument
- Gas Generator
- Engineering Device
Mass flow controllers
- Digital Mass Flow Controller DF-200C SERIES
- Digital Mass Flow Controller DF-250C SERIES
- Digital Mass Flow Controller with Indicator DF-300C SERIES
- Digital Mass Flow Controller with Indicator DF-350C SERIES
- All-Metal Digital Mass Flow Controller DF-550C SERIES
- Mass Flow Controller/Mass Flow Meter with Indicator MODEL D8500 SERIES
- Mass Flow Controller/Mass Flow Meter with Indicator MODEL 8500 SERIES
- Standard Mass Flow Controller MODEL 3660 SERIES
- High-grade Mass Flow Controller MODEL 3200 SERIES
- Low-cost Metal Sealed Mass Flow Controller/Meter MODEL 5400 SERIES
- High Grade Metal Seal Mass Flow Controller MODEL 5100 SERIES
- Compact Handy Mass Flow Control/Measurement UnitFLOW COMPO
- Mass Flow Controller/Mass Flow Meter with Indicator MODEL D8500 SERIES
- Mass Flow Controller/Mass Flow Meter with Indicator MODEL 8500 SERIES
- Low-cost Metal Sealed Mass Flow Controller/Meter MODEL 5400 SERIES
- Low-cost Mass Flow Meter with Display MODEL 3810DSII SERIES
- High-grade Mass Flow Meter MODEL3100 SERIES
- Standard Mass Flow Meter MODEL3760 SERIES
- Low-cost Mass Flow Sensor MODEL3810S SERIES
- Low-cost Digital Mass Flow Meter MODEL D3810 SERIES
- Compact Handy Mass Flow Control/Measurement Unit FLOW COMPO
- Compact Readout Unit MODEL CR-400
- Flow Indicators MODEL DPM-3
- Flow Setting Device MODEL CK SERIES
- Mass Flow Controller/Meter Power Units MODEL PSK-FB SERIES
Water Signal Flow Indicator Maeda Koki
If you want to use the mixed oil of the like, lubricants, please note the “Aburaaka”. When the inside or within the fluid piping “garbage” and “iron powder” is mixed, there is a possibility that the ball (float) may not work. We hope the use of the filter or the like.
Model and type MK series Oil and Water Signal produced by Maeda Koki Japan :
Flow rate visual type oil signal (flow cytometry)
- MKT type Oil signl
- flow rate of the oil with the naked eye.
- MKTV type OIL SIGNAL
- With flow rate adjustment valve
- MKCT type OIL SIGNAL
- with protective cover
- MKCTV type OIL SIGNAL
- With protective cover
- With flow rate adjustment valve
- MKCM type OIL SIGNA
- The electrical contacts type galvanometer with reed switch.
- with protective cover
- You can specify the operation flow rate of the switch.
Galvanometer type oil signal (flow cytometry)
- MK type OIL SIGNAL
- You can check the flow of oil in the visual motion of the ball.
- MKC type OIL SIGNAL
- You can check the flow of oil in the visual motion of the ball.
- with protective cover
- MKK type OIL SIGNAL
- You can check the flow of oil in the visual motion of the ball.
- With chuck sleeve copper tube conclusion
- MKK25-8-P
- You can check the flow of oil in the visual motion of the ball.
- With chuck sleeve copper tube conclusion
- MKC20-8-P
- You can check the flow of oil in the visual motion of the ball.
- With chuck sleeve copper tube conclusion
- with protective cover
- MKD type OIL SIGNAL
- You can visually check a small flow rate dropping situation.
- MKDV type OIL SIGNAL
- You can visually check a small flow rate dropping situation.
- With flow rate adjustment valve
Flow indicator
- FITV
- flow to distribute the fluid
- With flow rate adjustment valve
Switch with flow indicator
- FITVM
- flow to distribute the fluid
- With flow rate adjustment valve
- with flow switch
Flow rate visual type water signal (flow cytometry)
- MKC type WATER SIGNAL
- You can see with the naked eye the flow of water in the movement of the ball.
- with protective cover
- ※ If you want to see the approximate flow rate MKCT Please choose the type.
Paperless Recorders
The new PR series paperless recorders are launched in full product range with outstanding specifications and features. PR series includes a low-cost PR10, a popular PR20 and a high-end PR30. Compared with the first generation VR series, PR series offers much more, for example recorders in 4.3” & 12.1” displays in addition to 5.6”, 100 msec. sampling rate, external channels, batch, custom display, more strict FDA 21 CFR part 11, handwriting messages, SD slot, 2 USBs, pulse input, field calibration, Web Server, email, 19 languages, IP65, and yet in shorter depth 167mm.
- Ovens – Furnaces – Kilns
- Environmental Chambers
- 21 CFR21 Part 11 FDA Requirements
- AMS2750E Heat Treating Requirements
- Boilers
- Sterilizers / Autoclaves
- Power Generation Variables
- Flow Applications / Totalizers
- Water / Waste Water Flow
- Test & Measurement Applications
Features
- Touch Screen, TFT, 65K color
- 100 msec. scan rate
- Internal memory: 256 MB Flash
- CPU: ARM Cortex-A8, 1Ghz
- Standard: Ethernet, SD slot & USB
- Option: RS232/422/485 & Pulse input
- Protection: IP65 front & IP20 rear
- Standards: CE, cULus & RoHS
- Pulse input for flow applications
- Direct Printer connectivity
- Webserver & Email directly from Recorder
- Remote IO channels, Virtual channels
- Master & Slave, Modbus RTU and TCP protocols
- Custom display pages similar to HMI
- Batch operations, built in security & FDA 21 CFR part 11
- 19 international languages
PR10 – low-cost paperless recorder
PR20 – popular paperless recorder
PR30 – high-end paperless recorder
Faktor Penting Menentukan Jenis Flow Meter
Ada berbagai jenis fluida dengan karakteristik masing-masing yang perlu diketahui saat akan menentukan jenis flow meter serta persyaratan dari kecepatan aliran fluida seperti :
- Besarnya tekanan pressure,
- Besarnya temperature cairan,
- penurunan tekanan yang disyaratkan,
- Density cairan, viscosity dari fluida, konduktivitasnya, tingkat keasaman,
- dan untuk uap perlu juga diketahui temperature kerjanya, informasi tentang keselamatan atau toksisitas harus disediakan, data rinci tentang komposisi fluida, adanya gelembung/busa, soliditas (ukuran kasar atau lembut, partikel, serat), Perlu finishing jenis coating, dan kualitas tembus pandang / transmisi cahaya (buram, tembus atau transparan).?
Koneksi, Pipa dan Installasi Flow Meter
Para Perencana dalam menentukan jenis flow meter harus tahu apakah ada getaran yang terlalu besar atau adanya medan magnet atau mungkin di daerah tersebut, apakah tersedia tenaga listrik atau hanya mengandalkan mekanik atau pneumatik, jika kawasan ini diklasifikasikan untuk daerah yang mudah terbakar atau mudah meledakatau jika ada persyaratan khusus lain seperti peraturan yang sesuai dengann sanitary atau tempat yang harus bersih.
Ketika akurasi flowmeter dinyatakan dalam % CS atau unit % FS, kesalahan besar akan muncul jika flow rate mengalami penurunan secara drastis. Jika error pengukuran dinyatakan dalam % AR, error secara han secara absolut tetap sama pada kecepatan aliran yang maksimal maupun yang minimal. Karena skala penuh (FS) selalu merupakan jumlah yang lebih besar dari rentang dikalibrasi (CS), sebuah sensor dengan kinerja % FS akan selalu memiliki error yang lebih besar dari satu dengan spesifikasi % CS yang sama. Oleh karena itu, dalam rangka untuk membandingkan semua jenis yang ditawarkan, disarankan untuk mengkonversi semua angka error yang muncul ke dalam unit yang sama %AR.
Jika terdapat kinerja flow meter yang telah cocok dan terdapat dua jenis flow meter yang berbeda type dimana jenis flow meter pertama memiliki bagian yang begerak sedangkan jenis flowmeter yang kedua tidak memiliki bagian yang bergerak, pilihlah satu jenis flow meter yang tidak mempunyai bagian yang bergerak. Flow meter dengan jenis Bagian yang bergerak akan mempunyai potensi sumber masalah, tidak hanya untuk alasan yang jelas keausan, pelumasan, dan kepekaan terhadap lapisan, tetapi juga karena bagian yang bergerak membutuhkan banyak ruang pemeriksaan bahwa kadang-kadang menimbulkan “selip” ke dalam aliran yang diukur. Bahkan dengan flow meter yang terawat dengan baik dan dikalibrasi, akan ada variasi flow yang tidak terukur akibat perubahan viskositas fluida dan suhu. Perubahan suhu juga mengubah dimensi internal meter dan sehingga dibutuhkan konpensasi.
Selanjutnya, jika seseorang bisa mendapatkan kinerja yang sama dari kedua flowmeter penuh dan sensor titik, umumnya disarankan untuk menggunakan jenis flowmeter tersebut. Karena sensor titik tidak melihat aliran penuh, mereka membaca secara akurat hanya jika mereka dimasukkan ke kedalaman di mana kecepatan aliran rata-rata dari profil kecepatan di seluruh pipa. Bahkan jika titik ini adalah sangat menentukan/penting pada saat kalibrasi, bukan tidak mungkin untuk tetap tidak berubah, karena profil kecepatan berubah dengan laju aliran, viskositas, suhu, dan faktor lainnya.
Sage Gas Flow Sensors
Mass Flow Meter Coriolis RHM60
- Standard pressure ratings up to 490 bar (7107 psi)
- Temperature ratings from -196 to 350°C (-320 to 662°F)
- Mass flow uncertainty down to 0.15%
- Density uncertainty down to 0.5%
- Repeatability better than 0.05%
- Typical measuring ranges between 60 and 3000 kg/min
- Accurately measure low flow rates down to 45 kg/min
- Unique robust torsion driven oscillation system
- Process connection customization available
- Approved for use in hazardous areas
- Stainless steel case
- Remote and compact transmitter versions available
- Plant Balance
- Terminal Transfer
- Asphalt/Bitumen and Other High Temperature Fluids
- Viscous Fluids
- Reactor Charging
- Batching
- Barge, Ship, Rail Car and Truck Filling
- Torsion oscillator design assures a stable and drift free measurement with excellent signal to noise ratios
- Resilient to external noise and vibration
- Insensitive to pipe pressure changes
- Robust tube wall thickness provides increased operational safety in abrasive Applications
- Corrosion resistant
- Long sensor life guaranteed due to low mechanical stresses in the meter mechanism
- No moving parts to wear or fail
Coriolis Mass Flow Transmitter RHE07/08
The RHE07 transmitter can be used with an RHM sensor in a hazardous area (RHE07 in safe area).CSA certified versions of the RHE07 must be mounted in a safe area.
Features
- Wall mount or rack mount versions
- Built in safety barriers allow operation with RHM sensor in hazardous area
- Selectable metric and English units for Mass, Volume, Density and Temperature
- Configurable pulse/frequency output
- Dual Analog outputs (0/4 – 20/22 mA) individually configurable for Mass, Volume, Density or temperature
- Configurable digital outputs for status and alarm
- Configurable digital inputs for batch control, zeroing and totalizer operations
- Connectivity to control systems with optional digital data interfaces: RS422, RS485, RS232 or HART over analog
- Simple user interface – LCD display and three push buttons with intuitive menu design
- Password protected setup
- Single stage and two stage batch control functions
- Brix measurement
- % solids and concentration measurement
- Live density measurement on meters 1″/DN25 and above
- Unique FIXDENS function allows density calculation with small size meters
- Standard gas volume function
- Power consumption less than 15 W
- RHE07c double pulse output version available for dispenser applications
Applications
- General and critical process flows
- Filling, batching and dispensing
- Feed stocks and transfers
Benefits
- Different packages with the same operation and menu structure – only one instrument to learn and operate
- Common spare parts
- Works with all sizes of Rheonik RHM flow sensors
- Remote electronics provides installation flexibility
RHE07/08 Dimention
RHE07/08 General Specifications