Electromagnetic Flowmeter WMX Series

The WMX-Series are fanged electromagnetic fow meters for use in 4” to 10” pipe in municipal or industrial water and waste water applications where propeller meters have typically been used in the past. Because the WMX has no moving parts and has electrodes designed to discourage fouling, this magmeter performs well and requires much less frequent maintenance in applications where debris would impede propeller meters. 

There is no rotor to stop turning or bearings to wear out. Minimal straight pipe requirements allow WMX-Series meters to be used in piping confgurations where there is little space between the meter and an elbow.In chemical injection applications, the meter should be placed upstream of the injection line or far enough downstream for thorough mixing to occur before the meter.Rate and total indication are standard on both models. 

Units are customer-selected and factory-set. No set-up is required.The WMX101 is externally powered with 7-26 Vdc at 30 mA max (see NOTE in Specifcations). Two Lithium 3.6V “AA” batteries provide auxiliary power during power failures, allowing the meter to continue recording fow rate and total without interruption for the duration of the outage. Where external power loss is infrequent, battery life should exceed 10 years.



The 20-foot power cable also provides pulse output for use with a variety of Seametrics and other displays and controls for remote reading, data logging, pulse-to-analog conversion, and telemetry applications. High frequency pulse rate (required for use with 4-20 mA converters) is standard; additional pulse rates are optional.

The WMX104 is a battery-operated unit for use when pulse output is not required. The Lithium 3.6V “D” batteries are replaceable with an approximate 1-year life under continuous use, or more depending on the duty cycle. An optional input/output cable can be installed post-factory if needed for changing applications.



FEATURES

  • Simple and economical as a mechanical meter
  • No moving parts
  • Built-in pulse output
  • Minimal straight pipe required
  • Continuous battery or external power
  • Data logger compatible
  • Telemetry-ready

APPLICATIONS

  • Municipal water/waste water
  • Industrial water/waste water
  • Cooling tower water treatment
  • Well usage reporting
Specification 



Electromagnetic Flowmeter EX800 Series

Description :
– Low-flow performance and accuracy superior to any mechanical flow sensor
–  No moving parts to wear out
– Dedicated fittings for simplicity
– Retainer clip automatically sets correct depth
– Meter extends only about 1/8 of pipe diameter, minimizing potential for clogging with debris
– Simple pulse train output can be used with any SeaMetrics signal processing module, or sent directly to a PLC
– Available for pipe sizes 1″ to 8″, in brass, 316 stainless, and PVC

Electromagnetic Flowmeter EX110 Series

Description :
– Depth adjustable sensors
– EX110 fits any 1-1/2″ pipe fitting (standard saddle, for instance) and adjusts to pipe sizes 3-10″
– EX210 adjusts to pipe sizes 10-48″
– Meter extends only about 1/8 of pipe diameter, minimizing potential for clogging with debris
– Accept Seametrics modules for rate and total indication, 4-20 mA conversion, data logging, and flow switching
– Alternatively, signal can be sent directly to a PLC or other control
– Available in brass or 316 stainless steel
– Immersibility and reverse flow output available

Ultrasonic Flowmeter TDS100H

Description :
 Handheld Ultrasonic Flowmeter 
    Type : Handheld Flow Meter TDS 100 H
    Specification
    Accuracy : Better than 1% .
    Repeatability : 0.2%
    Flow range    :  0~±40 ft/s (0~±12 m/s)
    Display. : 2 line LCD
    Operate with clamp-on transducers.
    Power : Ni-MH Battery life for up to 12 hours continuous operation.

INLINE ULTRASONIC FLOWMETER

Description :
1: operating power :AC 85—264V or isolation DC 24V
2: current: 50mA(under the condition of connection without keyboard display and sound of buzzer)
3:output optional: one channel standard isolation RS485 output
              One channel isolation 4-20mA or 0-20mA passive output.
              Two channel OCT output(programmed between the pulse width(6-1000ms),default before leaving factory (200ms))
4:input optional: two channel three wire system PT100 platinum resistor input loop,to make heat meter has the function of displaying heat quantity.
5:display:2*10 backlit LCD(Chinese and English optional)
6: operating:magnetic 4 keypads to operate
7:other functions: automatic memory the positive,negative,net totaliser or flow rate and heat quantity of the last 512 days,128 months,10years
             Automatic memory the time of power turning on and off and flow rate of the last 30 times, realize to compensate by hand or automatically read the datas through Modbus communication protocol.
8:protection level:IP68


OPTIONAL ACCESSORY:


1:PT100 three wire platinum resistor( a pair,used for heat meter)
2:ultrasonic thickness gauge: (measure the thickness of pipe,reduce error,increase accuracy)

CLAMP ON TDS 100F

Description :
Wall mount Ultrasonic Flow meter
    Model : TDS100F
    Sensor type : Clamp On

LEVEL SENSOR TDS200








The ultrasonic level meter is the intelligent non-contact liquid level measuring instruments.
Product has automatic power adjustment, gain control, to a false target, and temperature compensation. U.S. imports of chip processing and advanced testing computing technology to improve the measurement accuracy of the instrument, for the interference signal suppression function to ensure that the real measurement results. The products can be widely used for a high degree of measurement of the level of a variety of liquid and solid materials can also be used for distance measurement.

Performance :

  • Range : 0.5 ~ 30 m
  • Accuracy : 0.25%,0.5%
  • Resolution : Range 10m : 10mm
  • Frequency : ~40KHZ
  • Launch angle : 6 º~12º
  • Blind area : 0.20~0.9m
  • Show : LCD
  • Supply voltage : 220VAC/24VDC
  • Output signal : 4~20mA Standard (Or optional RS485.RS232 when ordering)
  • Maximum load : 750 Ohm
  • Case Material : PA6.ABS
  • Degree of protection : IP65. IP67. IP68
  • Ambient temperature : -20~+55
  • Mounting thread : M66x3

Electromagnetic Flowmeter TDS100W

Description :
In line Ultrasonic Water Meter
     Type : TDS 100 W
    Material : Carbon steel
    Display : 96 segments LCD
    Operating power : 3.6 V lithium battery ( 5 years)
    Operations : two keypad
    Protection level : IP68
    Brand : Dalian, China

SPOT LIGHT WERMA

 Description :
 SPOT LIGHT WERMA
 Serial Number : 890 220 55
 Voltase : 24 v
 GN
 ta 50 Deg C